Question
After successfully installing the Intel drivers and xpu-smi utility, I get the following error when trying to query the AMC FW on my SYS-611C-TN4R with Intel GPU Flex 140. 

Command: sudo xpu-smi discovery --listamcversions -u <BMC_USER> -p <BMC_PASS> 
Message: "Error: No AMC are found"
Print
Answer
Please check that the Host Interface setting is enabled in the BMC. 
(Configuration -> BMC Settings -> Host Interface) 

If not, please enable and reboot the system and query the AMC FW again. 

The host interface setting in the BMC acts a direct communication channel between the system’s Host OS and the BMC. Enabling this setting allows the command to query the AMC FW version using Redfish API in the backend.   
Was this FAQ helpful?
Enter Comments Below:
Note: Your comments/feedback should be limited to this FAQ only. For technical support, please send an email to .
Enter your email address below if you'd like technical support staff to reply:
Please type the Captcha (no space)
Q F 8 E
Find more questions
Still Need Support?
Having trouble finding what you're searching for? Contact our support team for further assistance.

Certain products may not be available in your region