Question
I have problems using 64-bit PCI slots on P4DC6+/P4DC6+II when Adaptec 2005S is used, what should I do?
Print
Answer
Since these 2 64-bit PCI slots share IRQ with onboard SCSI (or RAID when it is used), the speed of these 2 slots must be reduced from 66MHz to 33MHz. Please change jumper JPA3 from "Open" to "Close" to set the speed to 33MHz.