Question
Datapath VisionSC-HD4+ cards are PCIe Gen3 x8. On a SYS-741GE-TNRT with an X13DEG-QT, Link Speed set to Auto does not train. Setting the same slots to Gen2 makes the cards work. What BIOS settings let them link at Gen3?

Print
Answer
Setup → Advanced → Chipset Configuration → North Bridge → IIO Configuration → the slot each VisionSC-HD4+ is in:

  Link Speed: Gen 3 (8 GT/s)
  Data Link Feature Exchange: Disable

On BIOS 2.9, Equalization Bypass To Highest Rate is not under each slot. Set it once, globally, under PCIe IIO Configuration Options:

  Equalization Bypass To Highest Rate: Disable

Leave PCIe ASPM Support (Global) disabled, IIO eDPC Support disabled, and PCIe PLL SSC disabled if those were already set for a VisionSD8 in the same system.

Save and exit. Shut down and unplug both power cords for at least one minute.

This links the VisionSC-HD4+ at Gen3 and the cards remain functional.