BMC Configuration Examples

You can integrate current APIs into their software and applications in order to receive all services provided by Redfish APIs.

Manager ResetToDefaults

URI: /redfish/v1/Managers/1/Actions/Manager.ResetToDefaults

Method: POST

ResetType: PreserveNetworkAndUsers, ResetAll

Payload:

{

"ResetType":"(ResetType)"

}

Response: 200

{

"Success": {

"code": "Base.v1_10_3.Success",

"message": "Successfully Completed Request."

}

}

System Reset

URI: /redfish/v1/Systems/1/Actions/ComputerSystem.Reset

Method: POST

ResetType: AllowableValues:[ "On","ForceOff","GracefulShutdown","GracefulRestart","ForceRestart","Nmi","ForceOn", "PowerCycle"]

Response: 200

{

"Success": {

"code": "Base.v1_10_3.Success",

"message": "Successfully Completed Request."

}

}

Enable/Disable S5 Standby Fan Mode

Note: This function is supported beginning with Gen 14 motherboards.

URI: /redfish/v1/Chassis/1

Method: PATCH

AllowableValues: true, false

Payload:

{

"Oem": {

"Supermicro": {

"StandbyPowerControl": {

"AIOMEnabled": true

}

}

}

}

Response: 200

Clear CMOS

Note: This function is supported beginning with Gen 14 motherboards.

URI: /redfish/v1/Systems/1/Actions/ComputerSystem.Decommission

Method: POST

Payload:

{

"OEMDecommissionTypes": [

"ClearCMOS"

]

}

Response: 200

Note: AC power will automatically restart.

Remote Standby Power Cycle

Note: This function is supported beginning with Gen 14 motherboards.

URI: /redfish/v1/Systems/1/Actions/Oem/OemSystemExtensions.Reset

Method: POST

Response: 200

Payload:

{

"ResetType": "ACCycle"

}

Notifications

SNMP

URI: /redfish/v1/Managers/1/NetworkProtocol

Method: PATCH

Payload:

{

"SNMP": {"ProtocolEnabled": true}

}

SNMPv2

URI: /redfish/v1/Managers/1/NetworkProtocol

Method: PATCH

Payload:

{

"SNMP": {"EnableSNMPv2c": true}

}

SNMPv3

URI: /redfish/v1/Managers/1/NetworkProtocol

Method: PATCH

Payload:

{

"SNMP": {"EnableSNMPv3": true}

}

Syslog

URI: /redfish/v1/Managers/1/Oem/Supermicro/Syslog

Method: PATCH

Payload:

{

"EnableSyslog": true,

"SyslogPortNumber": 514,

"SyslogServer": "10.136.176.16"

}

GET Syslog

  • Before BMC firmware versions Gen 13 1.10 and Gen 14 1.08:

    URI: /redfish/v1/Managers/1/Oem/Supermicro/Syslog

    Method: GET

    {

    "@odata.type": "#Syslog.v1_0_1.Syslog",

    "@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/Syslog",

    "Id": "Syslog",

    "Name": "Syslog",

    "EnableSyslog": false,

    "SyslogServer": "",

    "SyslogPortNumber": 0

    }

  • Since BMC firmware versions Gen 13 1.10 and Gen 14 1.08:

    URI: /redfish/v1/Managers/1/Oem/Supermicro/Syslog

    Method: GET

    {

    "@odata.type": "#Syslog.v1_0_2.Syslog",

    "@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/Syslog",

    "Id": "Syslog",

    "Name": "Syslog",

    "EnableSyslog": false,

    "SyslogServer": [

    {

    "ServerIP": "xxx.xxx.xxx.xxx",

    "Port": (integer)

    },

    {

    "ServerIP": null,

    "Port": null

    },

    {

    "ServerIP": null,

    "Port": null

    }

    ],

    "@odata.etag": "\"fa6d9d38cfa24edbec2b9ddd4ddfe5e4\""

    }

PATCH Syslog

  • Before BMC firmware versions Gen 13 1.10 and Gen 14 1.08:

    URI: /redfish/v1/Managers/1/Oem/Supermicro/Syslog

    Method: PATCH

    Payload:

    {

    "EnableSyslog": true,

    "SyslogPortNumber": 514,

    "SyslogServer": "10.136.176.16"

    }

  • Since BMC firmware versions Gen 13 1.10 and Gen 14 1.08:

    URI: /redfish/v1/Managers/1/Oem/Supermicro/Syslog

    Method: PATCH

    Payload:

    {

    "EnableSyslog": true,

    "SyslogServer": [

    {

    "ServerIP": "1.2.3.4",

    "SyslogPortNumber": 514

    }

    ]

    }

FanMode

URI: /redfish/v1/Managers/1/Oem/Supermicro/FanMode

Method: PATCH

Payload:

{

"Mode": "FullSpeed"

}

Mode Allowable Values: {"Standard", "FullSpeed", "Optimal", "PUE2","HeavyIO"}

GET FanMode

URI: /redfish/v1/Managers/1/Oem/Supermicro/FanMode

Method: GET

Response:

{

"@odata.type": "#FanMode.v1_0_1.FanMode",

"@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/FanMode",

"Name": "FanMode",

"Id": "Fan Mode",

"Mode": "Standard",

"Mode@Redfish.AllowableValues": [

"Standard",

"FullSpeed",

"PUE2",

"HeavyIO"

],

"@odata.etag": "\"5b0d65aea89689a2e4ee563be7865b98\""

}

PATCH FanMode

URI: /redfish/v1/Managers/1/Oem/Supermicro/FanMode

Method: PATCH

All Allowable Values for Mode: Standard, FullSpeed, PUE2, HeavyIO, PUE3, LiquidCooling, Smart, PUEOptimalSpeed, SmartCoolingSpeed, Performance, Silent

Note: Not all modes are supported on every system; to know which are supported on your system, check Mode@Redfish.AllowableValues. Silent and Performance mode are currently only supported on X14SAE/X14SAE-F.

Payload:

{

"Mode": "(value)"

}

NTP

URI: /redfish/v1/Managers/1/Oem/Supermicro/NTP

Method: GET

Response: 200

{

"@odata.type": "#NTP.v1_0_2.NTP",

"@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/NTP",

"Id": "NTP",

"Name": "NTP Service",

"NTPEnable": false,

"PrimaryNTPServer": "127.0.0.1",

"SecondaryNTPServer": "127.0.0.1",

"DaylightSavingTime": false,

"@odata.etag": "\"cb0e722d1a8a503198dc783ddaffbe2e\""

}

URI: /redfish/v1/Managers/1/NetworkProtocol

Method: PATCH

Payload:

{

"NTP": {

"ProtocolEnabled":"true",

"NTPServers":"127.0.0.1",

}

}

Response: 202

Note: Check the task monitor to check the progress for NTP.

GET NTP

  • Before BMC firmware versions Gen 12 1.14, Gen 13 1.12, and Gen 14 1.10:

    URI: /redfish/v1/Managers/1/Oem/Supermicro/NTP

    Method: GET

    Response: 200

    {

    "@odata.type": "#NTP.v1_0_2.NTP",

    "@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/NTP",

    "Id": "NTP",

    "Name": "NTP Service",

    "NTPEnable": false,

    "PrimaryNTPServer": "127.0.0.1",

    "SecondaryNTPServer": "127.0.0.1",

    "DaylightSavingTime": false,

    "@odata.etag": "\"cb0e722d1a8a503198dc783ddaffbe2e\""

    }

  • Supported since BMC firmware versions Gen 12 1.14, Gen 13 1.12, and Gen 14 1.10:

    URI: /redfish/v1/Managers/1/NetworkProtocol

    Method: GET

    Response: 200

    ...,

    "NTP": {

    "ProtocolEnabled": true,

    "NTPServers": [

    "172.31.44.202",

    "127.0.0.1"

    ],

    },

    ...

PATCH NTP

  • Before BMC firmware versions Gen 12 1.14, Gen 13 1.12, and Gen 14 1.10:

    URI: /redfish/v1/Managers/1/NetworkProtocol

    Method: PATCH

    Payload:

    {

    "NTP" : {

    "ProtocolEnabled":"true",

    "NTPServers":"127.0.0.1",

    }

    }

    Response: 200

    Note: Check the task monitor to view the progress for NTP.

  • Supported since BMC firmware versions Gen 12 1.14, Gen 13 1.12, and Gen 14 1.10:

    URI: /redfish/v1/Managers/1/NetworkProtocol

    Method: PATCH

    Payload:

    {

    "NTP": {

    "NTPServers": [

    "tock.stdtime.gov.tw",

    "watch.stdtime.gov.tw",

    "time.stdtime.gov.tw"

    ]

    }

    }

Clear NTP Servers

Note: This feature is supported since BMC firmware versions Gen 12 1.14, Gen 13 1.12, and Gen 14 1.10.

URI: /redfish/v1/Managers/1/NetworkProtocol

Method: PATCH

Payload: One of the following:

  • {

    "NTP": {

    "NTPServers": [

    null,

    null,

    null

    ]

    }

    }

  • {

    "NTP": {

    "NTPServers": [

    "",

    "",

    ""

    ]

    }

    }

Response: 200

NTP AutoDST Enabled

URI: /redfish/v1/Managers/1

Method: PATCH

Allowable Value: false, true

Payload: 200

{

"AutoDSTEnabled": false

}

Note: AutoDSTEnabled can only be PATCH as true if the system supports changing time zones.

SmartPower

Supported platform: Gen 14

URI: /redfish/v1/Managers/1/Actions/Oem/SmartPower

Method: PATCH

Value:

  • For FlexTwin only: SmartPowerModeOn, HPCNPowerModeOn

  • For other platforms: SmartPowerModeOn, SmartPowerModeOff

Payload:

{

"Option": (value)

}

Response: 200

SyncTime

URI: /redfish/v1/Managers/1/Actions/Oem/SupermicroManager.SyncTime

Method: POST

Value: Host

Response: 200

{

"TimeSource": "Host"

}

RADIUS

URI: /redfish/v1/Managers/1/Oem/Supermicro/RADIUS

Method: PATCH

Payload:

{

"RadiusEnabled":true,

"RadiusServerIP":"127.0.0.1",

"RadiusPortNumber":1812,

"RadiusSecret":"SECRET"

}

Snooping

URI: /redfish/v1/Managers/1/Oem/Supermicro/Snooping

Method: GET

Response: 200

IP Access Control

The following two APIs have been supported since Gen 15.

  • /redfish/v1/Managers/1/Oem/Supermicro/IPAccessControl/FilterRules

  • /redfish/v1/Managers/1/Oem/Supermicro/IPAccessControl/FilterRules/num

GET IP Access Control

  • Before SmcIPAccessControl Ver. 1_1_0:

    URI: /redfish/v1/Managers/1/Oem/Supermicro/IPAccessControl

    Method: GET

    {

    "@odata.type": "#IPAccessControl.v1_0_1.IPAccessControl",

    "@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/IPAccessControl",

    "Id": "IP Access Control",

    "Name": "IP Access Control",

    "ServiceEnabled": false,

    "FilterRules": {

    "@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/IPAccessControl/FilterRules"

    }

    }

    Response: 200

  • Since SmcIPAccessControl Ver. 1_1_0:

    URI: /redfish/v1/Managers/1/Oem/Supermicro/IPAccessControl

    Method: GET

    {

    "@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/IPAccessControl",

    "@odata.type": "#SmcIPAccessControl.v1_1_0.SmcIPAccessControl",

    "Id": "IPAccessControl",

    "Name": "IP Access Control",

    "ServiceEnabled": true,

    "Rules": [

    {

    "Address": "192.1.21.1.100",

    "PrefixLength": 32,

    "Policy": "Accept"

    },

    {

    "Address": "192.1.21.2.0",

    "PrefixLength": 24,

    "Policy": "Drop"

    },

    {

    "Address": "fe80::abcd:1234",

    "PrefixLength": 64,

    "Policy": "Accept"

    }

    ]

    }

    Response: 200

Enable Service

URI: /redfish/v1/Managers/1/Oem/Supermicro/IPAccessControl

Method: PATCH

Payload:

{

"ServiceEnabled": true

}

Modifying Rules

  • To keep an item unchanged, use {} as its index.

  • To delete an item, use null as its index.

  • To modify an item, put the content as its index.

URI: /redfish/v1/Managers/1/Oem/Supermicro/IPAccessControl

Method: PATCH

Payload:

{

"Rules": [

null,

{

"Address": "192.168.3.1",

"PrefixLength": 24,

"Policy": "Drop"

},

{}

]

}

SMCRAKP

URI: /redfish/v1/Managers/1/Oem/Supermicro/SMCRAKP

Method: PATCH

Payload:

{

"Mode": "Enabled"

}

iKVM

URI: /redfish/v1/Managers/1/Oem/Supermicro/IKVM

Method: GET

Response: {"Mode": "Relative"}

{

"@odata.type": "#IKVM.v1_0_2.IKVM",

"@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/IKVM",

"Id": "IKVM",

"Name": "IKVM",

"Current interface": "HTML 5",

"URI": "/redfish/GyoehEnZlt76uco.IKVM"

}

Use response property, “URI”, above to prepend “https://${BMC_IP}“ and paste this complete URL in a browser to render HTML5 iKVM.

Example of launching URL: https://{BMC_IP}/redfish/Kk1D4UVATDja0Jw.IKVM

iKVM Mouse Mode

URI: /redfish/v1/Managers/1/Oem/Supermicro/MouseMode

Method: PATCH

Payload:

{

"Mode": "Relative"

}

Mode Allowable Values: "Absolute", "Relative", "Single"

KCS Channel Control

This API allows you to secure their environment by giving appropriate privileges to access the KCS interface.

URI: /redfish/v1/Managers/1/Oem/Supermicro/KCSInterface

Method: PATCH

Payload:

{

"Privilege": "Administrator"

}

Privilege Allowable Values:

  • Administrator: Users accessing KCS interface will be able to perform all the operations that the administrator user can.

  • Operator: Users accessing KCS interface will be able to perform all the operations that users with Operator privileges can.

  • User: Users accessing the KCS interface will be able to perform all the operations that users with User privileges can.

  • Callback: This is the lowest privilege level. Only commands necessary to support initiating a Callback are allowed.

  • DisableKCS: Disabling KCS function, supported since KCS version 1.1.0; you can check in "@odata.type".

URI: /redfish/v1/Managers/1/Oem/Supermicro/KCSInterface

Method: GET

Response: 200

{

"@odata.type": "#KCSInterface.v1_1_0.KCSInterface",

"@odata.id": "/redfish/v1/Managers/1/Oem/Supermicro/KCSInterface",

"Id": "KCSInterface",

"Name": "KCS Interface",

"Privilege": "Administrator",

"@odata.etag": "\"7f21b53f195494a7c2dad2008917b1d7\""

}

Getting MAC Addresses from System NICs

URI: /redfish/v1/Systems/1/EthernetInterfaces/1

Method: GET

Response: 200

{

"@odata.type": "#EthernetInterface.v1_5_2.EthernetInterface",

"@odata.id": "/redfish/v1/Systems/1/EthernetInterfaces/1",

"Id": "1",

"Name": "AOC_NIC1",

"Description": "AOC-GTG-i2T #1",

"Status": {

"State": "Enabled",

"Health": "OK"

}

"MACAddress": "7c:c2:55:06:00:56",

"SpeedMbps": 0,

"FQDN": ""

}

Chassis Intrusion

The user can set the option to Automatic and Manual to clear a chassis intrusion.

By default, the value is Manual. If PhysicalSecurity.IntrusionSensorReArm is set to Automatic, the chassis sensor should auto-reset once the cover is closed.

URI: /redfish/v1/Chassis/1

Method: PATCH

  • Value: HardwareIntrusion, Normal, TamperingDetected

    Payload:

    {

    "PhysicalSecurity": {

    "IntrusionSensor": "(value)"

    }

    }

  • Value: Automatic, Manual

    Payload:

    {

    "PhysicalSecurity": {

    "IntrusionSensorReArm": "(value)"

    }

    }

Network DNS

Supported Platforms

Supported BMC Firmware

Redfish User Guide Version

Gen 12

1.3.3 or later

Version 3.4

URI: /redfish/v1/Managers/1/EthernetInterfaces/1

Method: GET/PATCH

Payload:

{

"StaticNameServers":[

"10.10.10.1",

"10.10.10.2"

]

}

LLDP

GET SharedNetworkPorts Collection

URI: /redfish/v1/Managers/1/SharedNetworkPorts

Method: GET

Response: 200

{

"@odata.type": "#PortCollection.PortCollection",

"@odata.id": "/redfish/v1/Managers/1/SharedNetworkPorts",

"Name": "SharedNetworkPorts Collection",

"Description": "Collection of SharedNetworkPorts",

"Members@odata.count": 1,

"Members":[

{

"@odata.id": " /redfish/v1/Chassis/1/NetworkAdapters/1/Ports/1"

}

],

"@odata.etag": "894cb8ea4eb6da2fb62990a90f2d2859"

}

GET DedicatedNetworkPorts Collection

URI: /redfish/v1/Managers/1/DedicatedNetworkPorts

Method: GET

Response: 200

{

"@odata.type": "#PortCollection.PortCollection",

"@odata.id": "/redfish/v1/Managers/1/DedicatedNetworkPorts",

"Name": "DedicatedNetworkPorts Collection",

"Description": "Collection of DedicatedNetworkPorts",

"Members@odata.count": 1,

"Members":[

{

"@odata.id": "/redfish/v1/Managers/1/DedicatedNetworkPorts/1"

}

],

"@odata.etag": "2a446445042d962d51a0f0c17658d6e1"

}

GET DedicatedNetworkPorts Information

URI: /redfish/v1/Managers/1/DedicatedNetworkPorts/num

Method: GET

Response: 200

{

"@odata.type": "#Port.v1_8_0.Port",

"@odata.id": "/redfish/v1/Managers/1/DedicatedNetworkPorts/1",

"Id": "1",

"Name": "DedicatedNetworkPorts 1",

"Description": "DedicatedNetworkPorts 1 information",

"CurrentSpeedGbps": 1,

"MaxSpeedGbps": 1,

"LinkStatus": "LinkUp",

"LinkState": "Enabled",

"PortId": "1",

"PortProtocol": "Ethernet",

"LinkNetworkTechnology": "Ethernet",

"PortType": "BidirectionalPort",

"Status":{

"State": "Enabled",

"Health": "OK",

"HealthRollup": "OK"

},

"Ethernet":{

"AssociatedMACAddresses":[

"7C:C2:55:30:FB:F6"

],

"LLDPEnabled": false,

"LLDPReceive":{},

"LLDPTransmit":{"ChassisIdSubtype": "NotTransmitted", "ChassisId": "", "ManagementAddressIPv4": "", "ManagementAddressIPv6": "",…}

},

"Oem":{

"Supermicro":{

"@odata.type": "#SmcPortExtensions.v1_0_0.Ports",

"LLDPTransmitEnabled": false

}

},

"@odata.etag": "b253ce04be488af8d0daf5daa707e43e"

}

CPU Power Capping

Note: Supported since Gen 13.

Enable/Disable Power Capping

URI: /redfish/v1/Chassis/1/Controls/CPU_PowerLimit

Method: PATCH

Response: 200

Payload:

{

"ControlMode":"Manual"

}

License Required: SFT-DCMS-SINGLE

Priviledge Required: ConfigureManager

Allowable Values: "Disabled": Control by this API is disabled. "Manual": Capping value is controlled by "SetPoint".

Set CPU Power Capping

URI: /redfish/v1/Chassis/1/Controls/CPU_PowerLimit

Method: PATCH

Response: 200

Payload:

{

"SetPoint": 400

}

License Required: SFT-DCMS-SINGLE

Priviledge Required: ConfigureManager

Node Manager

Note: Supported beginning with Gen 14.

Enable/Disable Node Manager Policy Control

Enable/Disable All Domains

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager

Method: PATCH

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

{

"Status": {

"State": "Enabled"

}

}

Enable/Disable Individual Policy

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Policies/{PolicyID}

Method: PATCH

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

{

"Status": {

"State": "Enabled"

}

}

Enable/Disable Individual Domain

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Domains/{DomainName}

Method: PATCH

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

{

"Status": {

"State": "Enabled"

}

}

Set Node Manager Policy

Create Policy

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Policies

Method: POST

Response: 201

License Required: SFT-DCMS-SINGLE

Payload:

{

"CorrectionInMs" : 6000, // Correction Time

"Domain" : "CPUSubsystem", // Policy will be applied into the whole domain

"Limit" : 0, // User configure actual power limit for the assigned domain

"Id" : "5", // User configure actual policy ID, after POST, API will be .../Policies/5

"LimitException": "NoAction", // Exception Action

"PolicyStorage" : "Volatile", // Policy Storage Option

"PowerCorrectionType":"Auto", // Aggressive CPU Power Correction

"StatisticsReportingPeriod" : "PT1S", // Statistic Reporting Period in seconds

"Status" : {

"State" : "Enabled" // Policy Enabled or not

},

"Trigger": {

"TriggerLimit" : 0, // Policy Trigger Limit

"TriggerType": "AlwaysOn" // Policy Trigger Type

}

}

Modify Policy

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Policies/{PolicyID}

Method: PATCH

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

{

"CorrectionInMs" : 6000, // Correction Time

"Limit" : 0, // User configure actual power limit for the assigned domain

"LimitException": "NoAction", // Exception Action

"PolicyStorage" : "Volatile", // Policy Storage Option

"PowerCorrectionType":"Auto", // Aggressive CPU Power Correction

"StatisticsReportingPeriod" : "PT1S", // Statistic Reporting Period in seconds

"Status" : {

"State" : "Enabled" // Policy Enabled or not

},

"Trigger": {

"TriggerLimit" : 0, // Policy Trigger Limit

"TriggerType": "AlwaysOn" // Policy Trigger Type

}

}

Enable/Disable Policy

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Policies/{PolicyID}

Method: PATCH

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

{

"Status": {

"State": "Enabled" // To disable or enable policy

},

}

Delete Policy

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Policies/{PolicyID}

Method: DELETE

Response: 200

License Required: SFT-DCMS-SINGLE

Reset Node Manager Statistics

Reset Statistics per Domain

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Domains/{DomainName}/Actions/Domain.ResetStatistics

Method: POST

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

{

}

Reset Statistics per Policy

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Policies/{PolicyId}/Actions/Policy.ResetStatistics

Method: POST

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

{

}

Set Node Manager Power Draw Range

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Domains/{DomainName}

Method: PATCH

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

...

"Capabilities": {

"Max": 600,

"Min": 0

}

...

Set Total Power Budget

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Policies

Method: POST

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

{

"ComponentID": 255 // Each time with single ComponentID.

"Domain": "CPUSubsystem", //

"Limit": 1000, //

"PolicyStorage" // Persistent or Volatile

}

Reset Node Manager

URI: /redfish/v1/Managers/1/Oem/Supermicro/NodeManager/Actions/NodeManager.Reset

Method: POST

Response: 200

License Required: SFT-DCMS-SINGLE

Payload:

{

}