Installing the Chassis into the Rack

After the rails are installed on the CSE-HS101-R000NFP chassis and on the rack, the server can be installed in the rack. It is heavy and requires two to three people to lift.

Installing the Chassis

  1. Pull both middle rails out the front of the outer rail until each clicks to a stop.

  2. Align the inner rails on the chassis with the front of the middle rails.

  3. Slide the inner rails on the chassis into the middle rails, keeping the pressure even on both sides. When partially in, the locking levers will stop further progress.

  4. Press down the locking levers on the inside of the inner rails and push the chassis all the way into the rear of the rack. The front latches will click into place.

The chassis is now mounted in the rack. It can be pulled partially out for service by lifting both front latches.

Figure 12. Installing the Chassis into the Rack