System Specifications

Processors

Dual socket BR (LGA7529)

Intel® Xeon® 6900 series processors with P-cores with up to 128 C/256 T and up to 504 MB cache per CPU; supports up to 500 W TDP CPUs (liquid cooled)

Chipset

System on Chip

BIOS

AMI 64 MB SPI Flash

Memory

Slot Count: 24 DIMM slots

Max Memory (1DPC): Up to 6 TB 6400 MT/s ECC DDR5 RDIMM

Max Memory (1DPC): Up to 3 TB 8800 MT/s ECC DDR5 MRDIMM

Storage Drives

Up to 12 front hot-swap 2.5" NVMe drive bays

Two M.2 PCIe 5.0 x2 NVMe slots (M-key 2280/22110)

PCI Expansion Slots

Two PCIe 5.0 x16 FH/10.5"L slots

One 5.0 x16 AIOM slot (OCP 3.0 compatible)

Input/Output

LAN: One RJ45 1 GbE dedicated BMC LAN port

USB 3.0: Two rear ports and one front port

Video: One VGA port

Motherboard

X14DBM-AP; proprietary; ( LxW) 11.5" x 17.0" (292.1 x 431.80 mm)

Chassis

CSE-HS101-R000NFP; 1U rackmount; (WxHxD) 17.2" x 1.7" x 30.66" (437 x 43 x 778.7 mm)

System Cooling

Eight counter-rotating 40 x 40 x 56-mm fans

Direct-to-chip (D2C) cold plate

Power Supply A

Two 1600 W redundant (1 + 1) Titanium Level (96%) power supplies

Dimensions (WxHxL): 73.5 x 40 x 265 mm

AC Input:

1000 W: 100 – 127 VAC

1000 W: 100 – 127 VAC/50 – 60 Hz

1600 W: 200 – 240 VAC

1600 W: 200 – 240 VAC / 50 - 60 Hz

1600 W: 200 – 240 VDC / 50 – 60 Hz (for CQC only)

Output:

+12 V Max: 83.3 A/Min: 0 A (100 VAC – 127 VAC)

+12 V Max: 133.3 A /Min: 0 A (200 VAC – 240 VAC)

12 V SB Max: 3.5 A /Min: 0 A

12 V SB Max: 3.5 A

Output Type: Backplanes (gold finger)

Power Supply B

Two 2600 W redundant (1 + 1) Titanium Level (96%) power supplies

Dimensions (WxHxL): 73.5 x 40 x 265 mm

AC Input:

2600 W: 200 – 240 VAC

2600 W: 200 – 240 VDC (For CQC Only)

2600 W: 200 – 240 VAC/50 – 60 Hz

2600 W: 200 – 240 VDC / 50 – 60 Hz (for CQC only)

Output:

+12 V Max: 216 A/Min: 0 A (11.4 VDC – 12.6 VDC) (12 V output)

+12 V Max: 216 A/Min: 0 A (200 Vac – 240 Vac)

12 V SB Max: 3.5 A

Output Type:

Backplanes (gold finger)

Power Supply C

Two 2000 W redundant (1 + 1) Titanium Level (96%) power supplies

Dimension (WxHxL): 73.5 x 40 x 265 mm

AC Input:

1000 W: 100 – 127 VAC/50 – 60 Hz

1800 W: 200 – 220 VAC/50 – 60 Hz

2700 W: 200 – 240 VAC

1980 W: 220 – 230 VAC/50 – 60 Hz

2000 W: 220 – 240 VAC/50 – 60Hz (for UL only)

2000 W: 230 – 240 VAC/50 – 60 Hz

2000 W: 230 – 240 VDC/50 – 60 Hz (for CQC only)

Output:

+12 V Max: 83 A/Min: 0 A (100 VAC – 127 VAC)

+12 V Max: 150 A/Min: 0 A (200 VAC – 220 VAC)

+12 V Max: 225 A/Min: 0 A (200 VAC – 240 VAC)

+12 V Max: 165 A/Min: 0 A (220 VAC – 230 VAC)

+12 V Max: 166 A/Min: 0 A (230 VAC – 240 VAC)

+12 V 12 V SB: Max: 3.5 A/ Min: 0 A

Output Type: Backplanes (gold finger)

Operating Environment

Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)

Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)

Operating Relative Humidity: 8% to 90% (non-condensing)

Non-operating Relative Humidity: 5% to 95% (non-condensing)

Regulatory Compliance

FCC, ICES, CE, UKCA, VCCI, RCM, NRTL, CB

Certified Safety Models

HS101LC-R20X14

Applied Directives, Standards

Directives:

EMC/EMI: 2014/30/EU (EMC Directive)

Electromagnetic Compatibility Regulations 2016

FCC Part 15 Subpart B

ICES-003

VCCI-CISPR 32

AS/NZS CISPR 32

CISPR 32

CISPR 35

BS/EN 55032

BS/EN 55035

BS/EN 61000-3-2

BS/EN 61000-3-3

BS/EN 61000-4-2

BS/EN 61000-4-3

BS/EN 61000-4-4

BS/EN 61000-4-5

BS/EN 61000-4-6

BS/EN 61000-4-8

BS/EN 61000-4-11

Environment:

Delegated Directive (EU) 2015/863

Directive 2011/65/EU (RoHS)

REACH Regulation EC 1907/2006

WEEE Directive 2012/19/EU

California Proposition 65

Product Safety:

2014/35/EU (LVD Directive)

UL/CSA 62368-1 (USA and Canada)

Electrical Equipment (Safety) Regulations 2016

IEC/BS/EN 62368-1

Perchlorate Warning

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. Perchlorate Material-special handling may apply. See https://www.dtsc.ca.gov/hazardouswaste/perchlorate