Control Panel
Figure 2. Control Panel
|
Control Panel Features (1 Per Node) |
|
|---|---|
|
Feature |
Description |
|
Node Designator |
Indicates the node controlled by this particular control panel. Node A is located on the left of the chassis, node B is located on the right. |
|
Power Button |
The main power switch applies or removes primary power from the power supply to the server but maintains standby power. To force a power off, press and hold this button for four seconds. |
|
LAN LED |
Indicates network activity when flashing. |
|
Information LED |
Alerts the operator to several states as noted in the table below. |
|
UID Button/LED |
The unit identification (UID) button turns on or off the blue light function of the Information LED and a blue LED on the rear of the chassis. This LED is used to locate the server in large racks and server banks. |
|
Information LED |
|
|---|---|
|
Status |
Properties |
|
Solid red |
An overheat condition has occurred. |
|
Blinking red (1 Hz) |
Fan failure. Check for an inoperative fan. |
|
Blinking red (0.25 Hz) |
Power failure. Check for a non-operational power supply. |
|
Solid blue |
UID has been activated locally to locate the server in a rack environment. |
|
Blinking blue (1 Hz) |
UID has been activated remotely to locate the server in a rack environment. |
|
Blinking blue (2 Hz) |
BMC resetting |
|
Blinking blue (4 Hz) |
Setting BMC factory default |
|
Solid red with power LED blinking green |
RoT fault detected |
|
Blinking blue (10 Hz) with power LED blinking green |
RoT BIOS/BMC firmware updating |
|
Blinking blue and red (10 Hz) |
RoT recovery mode |