Control Panel

Figure 2. Control Panel

Control Panel Features (1 Per Node)

Feature

Description

Node Designator

Indicates the node controlled by this particular control panel. Node A is located on the left of the chassis, node B is located on the right.

Power Button

The main power switch applies or removes primary power from the power supply to the server but maintains standby power. To force a power off, press and hold this button for four seconds.

LAN LED

Indicates network activity when flashing.

Information LED

Alerts the operator to several states as noted in the table below.

UID Button/LED

The unit identification (UID) button turns on or off the blue light function of the Information LED and a blue LED on the rear of the chassis. This LED is used to locate the server in large racks and server banks.

Information LED

Status

Properties

Solid red

An overheat condition has occurred.

Blinking red (1 Hz)

Fan failure. Check for an inoperative fan.

Blinking red (0.25 Hz)

Power failure. Check for a non-operational power supply.

Solid blue

UID has been activated locally to locate the server in a rack environment.

Blinking blue (1 Hz)

UID has been activated remotely to locate the server in a rack environment.

Blinking blue (2 Hz)

BMC resetting

Blinking blue (4 Hz)

Setting BMC factory default

Solid red with power LED blinking green

RoT fault detected

Blinking blue (10 Hz) with power LED blinking green

RoT BIOS/BMC firmware updating

Blinking blue and red (10 Hz)

RoT recovery mode