Question
I purchased an AS-2021M-82R+ server plus a SIMLC+ and 3 fans, FAN1 to FAN3, were installed. Every time I reset the whole system (AC in and out), there will be FAN4~FAN8 fan speed going low event recorded in IPMI event log file. Is that normal?
Print
Answer
The system will detect that FAN4~8 FAN speed is lower than it expected, it could be fan stopped or was not installed. In this case, FAN4~FAN8 were not installed, so the system detects FAN4~FAN8 fan speed is going low. Please use SDREditor to remove undesired items from the SDR table like FAN4~FAN8.