Question
I have MBD-X11DPH-T and 2 AOC-SLG3-2M2 cards with 2 Seagate XP1920LE30002's installed in each.
I can see all 4 of the drives within BIOS, but I'm not seeing them within Server's disk manager or
diskpart via CMD. I know these drives work with the cards, and the cards work with every other X11
board, so I'm not sure what the issue is.
I installed VROC key and changed them out to CPU2 slots 4&5 (both x16). Still nothing within diskpart
or disk management. Which IIO bifurcation control set in BIOS for Slot 4 & slot 5 ,
or do I need to just do it by trial and error?
Print
Answer
Please try CPU2/IOU2(BR3) for slot4 x4x4x4x4 and CPU2/IOU1(BR2) for slot5 x4x4x4x4.