Question
We replaced the disk in slot 13 of the SuperStorage Server SSG-2029P-DN2R24L and it was verified that the BMC status was normalized and slot 13 status is OK.

However, according to the DMESG log, the module server detects the disk, but after the message "Powering on due to button press" it displays the error "link training error: status 0x1001" and "Failed to check link status". Looking at lsblk command, we confirmed that it continues to recognize only 21 disks instead of the expected 22.
Print
Answer
This indicates a communication failure between the NVMe and the controller which could be due to the cable or port on the drive backplane but since the BMC indicates that the drive is OK, it could be a driver related. You can try resolve the issue by reinserting the drive. If that doesn't resolve the issue, then try a system power cycle.