Question
We have version 2.0.0_build.605-20151230102403. It’s reporting OS shutdown/power up as “Critical”, should be “informational”?
Print
Answer
SSM shows SEL asserted error and all need to manually clear it.

Please follow the steps listed below to ignore OS shutdown/power event.

1. Perform innoutconfig command to export the configuration data to files from SSM database.

2. Open [SSM installation folder]/shared/config/builtin/ipmi_command.cfg

3. Find the command name of “check_ipmi_sel_health” and add “-ex 01,02,03,04,05:00,08:00,1F,20:02,20:03” as below

4. Perform innoutconfig command to import the configuration data to files into SSM database.

5. Restart the SSM Server.

Note: Please reference chapter of “Configuring the SSM Server with Files” and “SSM Utilities” in the SSM user guide for detail.