Question
I just received your SuperServer 6023P-8R. After powering on the system an error message “AIC 7902 B at slot 09, 06:02:01 SCSI Controller Configuration Error: 03” was displayed. I have cleared the CMOS and reset the Adaptec BIOS to default, but still have the same error on POST. Can it be a problem with the B channel?
Answer
There is no issue with the on-board SCSI B channel. For some reason, the on-board Adaptec SCSI Host Controller termination is disabled, please check and make sure jumper JPA2 is open to enable termination.
Was this FAQ helpful?
YES      NO

Enter Comments Below:
Note: Your comments/feedback should be limited to this FAQ only. For technical support, please send an email to support@supermicro.com.



 Enter your email address below if you'd like technical support staff to reply:


 Please type the Captcha (no space)
B C V 6

FAQ Stats
FAQ ID Related Category / Keyword Date Posted Code
3891 BIOS:
- AMI BIOS
- Award BIOS
- Phoenix BIOS
Storage:
- Adaptec AIC-7902 U320 SCSI
- U320 SCSI Controllers
10/29/05 DL


    Print Answer