Installing the Outer Rails onto the Rack
Each end of the assembled outer rail includes a bracket with hooks and square, spring-loaded pegs to fit into the square holes in your rack.
Important: Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.
Important: Do not pick up the server with the front handles. They are designed to pull the system from a rack only.
-
Confirm that the left and right outer rails have been correctly identified.
-
Press upward on the locking tab at the rear end of the middle rail.
-
Push the middle rail back into the outer rail.
-
Hang the hooks on the front of the outer rail onto the square holes on the front of the rack. If desired, use screws to secure the outer rails to the rack.
-
Pull out the rear of the outer rail, adjusting the length until it just fits within the posts of the rack.
-
Hang the hooks of the rear section of the outer rail onto the square holes on the rear of the rack. Take care that the proper holes are used so the rails are level. If desired, use screws to secure the rear of the outer rail to the rear of the rack.
-
Repeat for the other outer rail.