SYS-821GE-TNHR; the customer reported that when they used the SAA "GetCurrentBiosCfg" command, they encountered the following errors:
********************************************ERROR*****************************************
ExitCode = 65
Description = Invalid internal file
Program Error Code = 536.11
Error message:
Invalid BIOS internal file
Parsing error. AttributeName: COMMN093#0035 is not in the attribute map. ********************************************************************************************
The customer is using BIOS 2.7 and BMC 01.01.06. The issue was resolved after updating BMC to version 01.03.18.