Front View

The following features are located on the front of the SYS-212B-FN2T server.

Figure 1. SYS-212B-FN2T Front View

Front Features

Feature

Description

Control Panel

Front control panel with LEDs and buttons. See the Control Panel for more details.

Power Supplies

One 2000 W redundant Titanium Level (96%) power supply (PWS1 on the bottom)

One optional 2000 W redundant Titanium Level (96%) power supply (PWS2 on top)

LAN Port

One dedicated BMC LAN port

Two RJ45 10 GbE ports

USB Ports

Two USB 3.2 Gen1 ports

VGA Port

One video port

Server Handle

Two (left and right) handles supporting server removal.

Expansion Slot Locations

Slot

Option 1

Option 2

Option 3

1

N/A

PCIe 5.0 x16 FHHL

PCIe 5.0 x16 HHHL

2

N/A

N/A

N/A

3

N/A

PCIe 5.0 x16 HHHL

N/A

4

N/A

PCIe 5.0 x8 HHHL

N/A

5

PCIe 5.0 x16 FHHL

PCIe 5.0 x16 FHHL

PCIe 5.0 x16 FHHL

6

PCIe 5.0 x16 FHHL

PCIe 5.0 x16 FHHL

PCIe 5.0 x16 FHHL

Options 2 and 3 require additional parts from the Optional Parts list and limit processor to a lower TDP.

 

Power Supply Indicators

There are two power supply indicators on the rear of each power supply module. An amber light on the power supply is illuminated when the power is switched off. A green light indicates that the power supply is operating normally. These indicators also emit different behaviors to alert of the status of the power supply:

Power Supply Indicators

Power Supply Condition

Green LED

Amber LED

No A/C Power to Power Supply

OFF

OFF

Power Supply critical events causing

a shutdown/ failure/ OCP/ OVP/ Fan Fail/OTP/ UVP

OFF

ON (Steady)

Power Supply Warning Events Where the power supply continues to operate;

High temperature; Over voltage; under voltage, etc

OFF

ON (1 Hz Blinking)

AC present only 12 vsb on (PS off)

ON (1 Hz Blinking)

OFF

Output ON and OK

ON (Steady)

OFF

AC cable unplugged and in redundant mode

OFF

ON (Steady)