System Specifications
|
Processors |
|
Dual AMD EPYC™ 9005/9004 Series Processors in Socket SP5 with a Thermal Design Power (TDP) of up to 500 W Note: Dependent on thermal validation and system configuration. Contact a Supermicro representative for details. |
|
Chipset |
|
System on Chip (SoC) |
|
BIOS |
|
512 Mb AMI BIOS® SPI Flash BIOS ACPI 6.5, SMBIOS 3.7 or later, Plug-and-Play (PnP), RTC (Real Time Clock) wakeup, Riser Card Auto-Detection support |
|
Memory |
|
24 DIMM slots with 1DPC that support up to: 6 TB of ECC DDR5/3DS RDIMM at 6400 MT/s (AMD EPYC™ 9005 Series Processors) 6 TB of ECC DDR5/3DS RDIMM at 4800 MT/s (AMD EPYC™ 9004 Series Processors) Note: For details, refer to Memory Support. |
|
Storage Drives |
|
Up to 24 2.5" front hot-swap NVMe/SATA/SAS drive bays (drive options require additional parts) Two M.2 NVMe PCIe 3.0 x4 in the 2280 and 22110 form factors |
|
PCI Expansion Slots |
|
Optional: up to eight PCIe 5.0 x8 slots or four PCIe 5.0 x16 slots, or mix and match |
|
Input/Output |
|
One AIOM slot for flexible networking (OCP 3.0 compatible) Two USB 3.0 Type-A ports (rear) One VGA port One BMC GbE LAN port |
|
Motherboard |
|
H14DSH: proprietary 17" x 12.89" (431.8 mm x 327.4 mm) (WxL) |
|
Chassis |
|
CSE-HS201-R000NFP: 2U rackmount 17.2" x 3.5" x 31.74" (437 x 88.9 x 806.2 mm) (WxHxD) |
|
System Cooling |
|
Six 6-cm heavy-duty hot-swap fans with optimal fan speed control Two air shrouds |
|
Security |
|
Trusted Platform Module (TPM) support |
|
Power Supply |
|
Refer to the power supply table later in this appendix for details on this system's selectable power supply options. Note: For all power supplies, full redundancy is based on configuration and application load. |
|
Operating Environment |
|
(Operating temperature based on configurations) Operating Temperature: 10°C to 35°C (50°F to 95°F) Non-Operating Temperature: -30°C to 60°C (-30°F to 140°F) Operating Relative Humidity: 8% to 80% (non-condensing) Non-Operating Relative Humidity: 8% to 90% (non-condensing) |
|
Regulatory Compliance |
|
FCC, ICES, CE, UKCA, VCCI, RCM, NRTL, CB |
|
Certified Safety Models |
|
Compliant with UL or CSA: For PWS-1K24A-1R: HS201-R12H14 or HS201-12 For PWS-1K63A-1R: HS201-R16H14 or HS201-16 For PWS-2K07A-1R: HS201-R20H14 or HS201-20 For PWS-2K63A-1R: HS201-R26H14 or HS201-26 For PWS-1K31D-1R: HS201-R13DH14 or HS201-13D For PWS-1K60D-1R: HS201-R16DH14 or HS201-16D For PWS-2K04D-1R: HS201-R20DH14 or HS201-20D |
|
Perchlorate Warning |
|
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. Perchlorate Material-special handling may apply. See https://www.dtsc.ca.gov/hazardouswaste/perchlorate |
|
Applied Directives, Standards |
|
Directives: EMC/EMI: 2014/30/EU (EMC Directive) Electromagnetic Compatibility Regulations 2016 FCC Part 15 Subpart B ICES-003 VCCI-CISPR 32 AS/NZS CISPR 32 CISPR 32 CISPR 35 BS/EN 55032 BS/EN 55035 BS/EN 61000-3-2 BS/EN 61000-3-3 BS/EN 61000-4-2 BS/EN 61000-4-3 BS/EN 61000-4-4 BS/EN 61000-4-5 BS/EN 61000-4-6 BS/EN 61000-4-8 BS/EN 61000-4-11 Environment: Delegated Directive (EU) 2015/863 Directive 2011/65/EU (RoHS) REACH Regulation EC 1907/2006 WEEE Directive 2012/19/EU California Proposition 65 Product Safety: 2014/35/EU (LVD Directive) UL/CSA 62368-1 (USA and Canada) Electrical Equipment (Safety) Regulations 2016 IEC/BS/EN 62368-1 |
Power Supply Options
|
Model PWS-1K24A-1R: Two 1200 W redundant modules, 80 Plus Titanium level |
|
AC Input 1200 W: 200–240 VAC / 50–60 Hz / 7.5–6 A 800 W: 100–127 VAC / 50–60 Hz / 9.8–7 A DC Input: 1200 W: 230–240 VDC / 7–6 A (for CCC only) +12 V Max: 100 A / Min: 0 A (200–240 VAC) Max: 66.7 A / Min: 0 A (100–127 VAC) Max: 100 A / Min: 0 A (230–240 VDC) (for CCC only) 12 VSB Max: 2.1 A / Min: 0 A |
|
Model PWS-1K63A-1R: Two 1600 W redundant modules, 80 Plus Titanium level |
|
AC Input 1600 W: 200–240 VAC / 50–60 Hz / 9–7.5 A 1000 W: 100–127 VAC / 50–60 Hz / 12–9 A +12 V Max: 133.3 A / Min: 0 A (200–240 VAC) Max: 83.3 A / Min: 0 A (100–127 VAC) 12 VSB Max: 3.5 A |
|
Model PWS-2K07A-1R: Two 2000 W redundant modules, 80 Plus Titanium level |
|
AC Input 2000 W: 230–240 VAC / 50–60 Hz / 10–9.8 A 1980 W: 220–230 VAC / 50–60 Hz / 10–9.8 A 1800 W: 200–220 VAC / 50–60 Hz / 10–9.8 A 1000 W: 100–127 VAC / 50–60 Hz / 12–9 A +12 V Max 166 A and min 0 A (230–240 VAC) Max 165 A and min 0 A (220–230 VAC) Max 150 A and min 0 A (200–220 VAC) Max 83 A and min 0 A (100–127 VAC) 12 VSB Max: 3.5 A / Min: 0 A |
|
Model PWS-2K63A-1R: Two 2600 W redundant modules, 80 Plus Titanium level |
|
AC Input 2600 W: 200–240 VAC / 50–60 Hz / 15.0–12.5 A +12 V Max: 216 A / Min: 0 A (200–240 VAC) 12 VSB Max: 3.5 A |
|
Model PWS-1K31D-1R: Two 1300 W redundant modules |
|
DC Input 1300 W: -44 to -65 VDC / 40–27 A +12 V Max: 108.3 A / Min: 0 A 12 VSB Max: 2.1 A |
|
Model PWS-1K60D-1R: Two 1600 W redundant modules |
|
DC Input 1600 W: -40 to -60 VDC / Max 40 A +12 V Max: 133 A / Min: 0 A 12 VSB Max: 3.5 A / Min: 0 A |
|
Model PWS-2K04D-1R: Two 2000 W redundant modules |
|
DC Input 2000 W: -48 to -60 VDC / 55–43 A +12 V Max: 166.6 A / Min: 0 A 12 VSB Max: 4 A / Min: 0 A |