System Specifications

Processors

Dual AMD EPYC™ 9005/9004 Series Processors in Socket SP5 with a Thermal Design Power (TDP) of up to 500 W

Note: Dependent on thermal validation and system configuration. Contact a Supermicro representative for details.

Chipset

System on Chip (SoC)

BIOS

512 Mb AMI BIOS® SPI Flash BIOS

ACPI 6.5, SMBIOS 3.7 or later, Plug-and-Play (PnP), RTC (Real Time Clock) wakeup, Riser Card Auto-Detection support

Memory

24 DIMM slots with 1DPC that support up to:

6 TB of ECC DDR5/3DS RDIMM at 6400 MT/s (AMD EPYC™ 9005 Series Processors)

6 TB of ECC DDR5/3DS RDIMM at 4800 MT/s (AMD EPYC™ 9004 Series Processors)

Note: For details, refer to Memory Support.

Storage Drives

Up to 24 2.5" front hot-swap NVMe/SATA/SAS drive bays (drive options require additional parts)

Two M.2 NVMe PCIe 3.0 x4 in the 2280 and 22110 form factors

PCI Expansion Slots

Optional: up to eight PCIe 5.0 x8 slots or four PCIe 5.0 x16 slots, or mix and match

Input/Output

One AIOM slot for flexible networking (OCP 3.0 compatible)

Two USB 3.0 Type-A ports (rear)

One VGA port

One BMC GbE LAN port

Motherboard

H14DSH: proprietary 17" x 12.89" (431.8 mm x 327.4 mm) (WxL)

Chassis

CSE-HS201-R000NFP: 2U rackmount 17.2" x 3.5" x 31.74" (437 x 88.9 x 806.2 mm) (WxHxD)

System Cooling

Six 6-cm heavy-duty hot-swap fans with optimal fan speed control

Two air shrouds

Security

Trusted Platform Module (TPM) support

Power Supply

Refer to the power supply table later in this appendix for details on this system's selectable power supply options.

Note: For all power supplies, full redundancy is based on configuration and application load.

Operating Environment

(Operating temperature based on configurations)

Operating Temperature: 10°C to 35°C (50°F to 95°F)

Non-Operating Temperature: -30°C to 60°C (-30°F to 140°F)

Operating Relative Humidity: 8% to 80% (non-condensing)

Non-Operating Relative Humidity: 8% to 90% (non-condensing)

Regulatory Compliance

FCC, ICES, CE, UKCA, VCCI, RCM, NRTL, CB

Certified Safety Models

Compliant with UL or CSA:

For PWS-1K24A-1R: HS201-R12H14 or HS201-12

For PWS-1K63A-1R: HS201-R16H14 or HS201-16

For PWS-2K07A-1R: HS201-R20H14 or HS201-20

For PWS-2K63A-1R: HS201-R26H14 or HS201-26

For PWS-1K31D-1R: HS201-R13DH14 or HS201-13D

For PWS-1K60D-1R: HS201-R16DH14 or HS201-16D

For PWS-2K04D-1R: HS201-R20DH14 or HS201-20D

Perchlorate Warning

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. Perchlorate Material-special handling may apply. See https://www.dtsc.ca.gov/hazardouswaste/perchlorate

Applied Directives, Standards

Directives:

EMC/EMI: 2014/30/EU (EMC Directive)

Electromagnetic Compatibility Regulations 2016

FCC Part 15 Subpart B

ICES-003

VCCI-CISPR 32

AS/NZS CISPR 32

CISPR 32

CISPR 35

BS/EN 55032

BS/EN 55035

BS/EN 61000-3-2

BS/EN 61000-3-3

BS/EN 61000-4-2

BS/EN 61000-4-3

BS/EN 61000-4-4

BS/EN 61000-4-5

BS/EN 61000-4-6

BS/EN 61000-4-8

BS/EN 61000-4-11

Environment:

Delegated Directive (EU) 2015/863

Directive 2011/65/EU (RoHS)

REACH Regulation EC 1907/2006

WEEE Directive 2012/19/EU

California Proposition 65

Product Safety:

2014/35/EU (LVD Directive)

UL/CSA 62368-1 (USA and Canada)

Electrical Equipment (Safety) Regulations 2016

IEC/BS/EN 62368-1

Power Supply Options

Model PWS-1K24A-1R: Two 1200 W redundant modules, 80 Plus Titanium level

AC Input

1200 W: 200–240 VAC / 50–60 Hz / 7.5–6 A

800 W: 100–127 VAC / 50–60 Hz / 9.8–7 A

DC Input:

1200 W: 230–240 VDC / 7–6 A (for CCC only)

+12 V

Max: 100 A / Min: 0 A (200–240 VAC)

Max: 66.7 A / Min: 0 A (100–127 VAC)

Max: 100 A / Min: 0 A (230–240 VDC) (for CCC only)

12 VSB

Max: 2.1 A / Min: 0 A

Model PWS-1K63A-1R: Two 1600 W redundant modules, 80 Plus Titanium level

AC Input

1600 W: 200–240 VAC / 50–60 Hz / 9–7.5 A

1000 W: 100–127 VAC / 50–60 Hz / 12–9 A

+12 V

Max: 133.3 A / Min: 0 A (200–240 VAC)

Max: 83.3 A / Min: 0 A (100–127 VAC)

12 VSB

Max: 3.5 A

Model PWS-2K07A-1R: Two 2000 W redundant modules, 80 Plus Titanium level

AC Input

2000 W: 230–240 VAC / 50–60 Hz / 10–9.8 A

1980 W: 220–230 VAC / 50–60 Hz / 10–9.8 A

1800 W: 200–220 VAC / 50–60 Hz / 10–9.8 A

1000 W: 100–127 VAC / 50–60 Hz / 12–9 A

+12 V

Max 166 A and min 0 A (230–240 VAC)

Max 165 A and min 0 A (220–230 VAC)

Max 150 A and min 0 A (200–220 VAC)

Max 83 A and min 0 A (100–127 VAC)

12 VSB

Max: 3.5 A / Min: 0 A

Model PWS-2K63A-1R: Two 2600 W redundant modules, 80 Plus Titanium level

AC Input

2600 W: 200–240 VAC / 50–60 Hz / 15.0–12.5 A

+12 V

Max: 216 A / Min: 0 A (200–240 VAC)

12 VSB

Max: 3.5 A

Model PWS-1K31D-1R: Two 1300 W redundant modules

DC Input

1300 W: -44 to -65 VDC / 40–27 A

+12 V

Max: 108.3 A / Min: 0 A

12 VSB

Max: 2.1 A

Model PWS-1K60D-1R: Two 1600 W redundant modules

DC Input

1600 W: -40 to -60 VDC / Max 40 A

+12 V

Max: 133 A / Min: 0 A

12 VSB

Max: 3.5 A / Min: 0 A

Model PWS-2K04D-1R: Two 2000 W redundant modules

DC Input

2000 W: -48 to -60 VDC / 55–43 A

+12 V

Max: 166.6 A / Min: 0 A

12 VSB

Max: 4 A / Min: 0 A