Fail LED (Information LED for OH/FF/PF)
The Fail LED (Information LED for OH/Fan Fail/PWR Fail) connection, located on pin 4 of JFP1, provides warnings of overheating, power failure, or fan failure for the system.
For a detailed diagram of the X14SBH motherboard, see the layout under Motherboard Quick Reference.
|
Fail LED (Information LED) (OH/Fan Fail/PWR Fail) LED States |
|
|---|---|
|
Status |
Description |
|
Solid red (on) |
An overheat condition has occurred. |
|
Blinking red (1 Hz) |
Fan failure: check for an inoperative fan. |
|
Blinking red (0.25 Hz) |
Power failure: check for a non-operational power supply. |
|
Blinking red (10 Hz) (FP red LED) |
CPLD recovery mode error(s). |
|
Solid blue |
UID has been activated locally. Use this function to locate a unit in the system that might be in need of service. |
|
Blinking blue (1 Hz) |
Local UID has been activated locally on. Use this function to identify a unit that might be in need of service. |
|
BIOS/BMC blinking blue (10 Hz) |
BIOS/BMC: recovery and/or update in progress. |
|
Red Info LED blinking (10 Hz) and MB UID LED blue blinking (10 Hz) |
CPLD: recovery and/or update in progress. |