Fail LED (Information LED for OH/FF/PF)

The Fail LED (Information LED for OH/Fan Fail/PWR Fail) connection, located on pin 4 of JFP1, provides warnings of overheating, power failure, or fan failure for the system.

For a detailed diagram of the X14SBH motherboard, see the layout under Motherboard Quick Reference.

Fail LED (Information LED) (OH/Fan Fail/PWR Fail)

LED States

Status

Description

Solid red (on)

An overheat condition has occurred.

Blinking red (1 Hz)

Fan failure: check for an inoperative fan.

Blinking red (0.25 Hz)

Power failure: check for a non-operational power supply.

Blinking red (10 Hz) (FP red LED)

CPLD recovery mode error(s).

Solid blue

UID has been activated locally. Use this function to locate a unit in the system that might be in need of service.

Blinking blue (1 Hz)

Local UID has been activated locally on. Use this function to identify a unit that might be in need of service.

BIOS/BMC blinking blue (10 Hz)

BIOS/BMC: recovery and/or update in progress.

Red Info LED blinking (10 Hz) and MB UID LED blue blinking (10 Hz)

CPLD: recovery and/or update in progress.