Question
We use a CSE-826BE16-R920LPB with X9SRL-F and a AOC-S2208L-H8iR controller and are getting Consistency Check warnings. Also we see a lot of "patrol read aborted" log entries. What is the problem?
Print
Answer
Patrol read starts only when the controller is idle for a defined period of time and no other background tasks are active, though it can continue to run during heavy I/O processes. If this is not the case when Patrol read starts, you will see Patrol read aborted log entries and also "Consistency Check inconsistancy logging disabled, too many inconsistancies.