Question
We are using a X9DRW-iF. We are unable to establish a reliable connection to the dedicated IPMI management interface on the server.
When performing a continuous ping to the management network interface every other ping times out.
The dedicated IPMI nic has an IP configured & NIC 1 has no configuration as the OS has not been installed. The switch ports for NIC1 and the IPMI are on different VLANs.
Print
Answer
Please go to the browser and under network setting changed it from "Fail Over" to "Dedicated LAN" it fixes the issue of the IPMI network (MAC) address from being advertised on both the dedicated IPMI mgmt port and NIC1.
Was this FAQ helpful?