Question
Is there is any processor TDP limitation for SYS-6027TR-HTQRF? As previous generation server (4nodes in 2U barebone as well as 2nodes in 1U barebone) does not support 130W TDP.
Print
Answer
X9 2U Twin^2 servers support Sandy Bridge-EP TDP 115W processors at 35 degree C ambient temperature and TDP 130W processors at 30 degree C ambient temperature.
Was this FAQ helpful?