SuperServer SYS-120C-TN10R (Complete System Only)

1U CloudDC with 10 NVMe bays

SYS-120C-TN10R Main SYS-120C-TN10R Angle SYS-120C-TN10R Top SYS-120C-TN10R Front SYS-120C-TN10R Rear
Integrated Board: X12DDW-A6
Learn more

Key Applications

  • Web Server, Firewall Application
  • Data Center Optimized, Value IaaS
  • Cloud Computing, Compact Server
  • DNS & Gateway Servers, Firewall Application
  • CDN, Edge Nodes

Key Features

  1. Dual sockets P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors
  2. Intel® C621A Chipset
  3. 16 DIMMs up to 6TB 3DS ECC DDR4-3200: LRDIMM/RDIMM/Intel® Intel® DCPMM
  4. 2 PCIe 4.0 x16 FHHL;
    2 PCIe 3.0 x2 NVMe M.2
  5. Dual AIOM (OCP 3.0) slots with NCSI for networking, 1 dedicated IPMI LAN
  6. 10x 2.5" hot-swap hybrid NVMe/SATA/SAS drive bays
  7. 6 counter-rotating 4 cm PWM fans with optimal fan speed control, 2 air shrouds
  8. 860W redundant Platinum level 100-240Vac and 200-240 Vdc power supplies
  9. 1 VGA, 1 COM, 2 USB 3.0 (rear), 2 USB 2.0 (front)
...
...
Specifications Resources & Downloads Parts List
Specifications
Product SKUs
SuperServer SYS-120C-TN10R Standard version with PWS-860P-1R2 (Platinum Level)
SuperServer SYS-120C-TN10R-EU European version with PWS-861A-1R (Titanium Level)
Motherboard
Super X12DDW-A6
Processor
CPU
  • Dual Socket P4 (LGA-4189)
  • 3rd Gen Intel® Xeon® Scalable processors
Core Count
  • Up to 40C/80T; Up to 60MB Cache per CPU
Note
  • Supports up to 270W TDP CPUs (Air Cooled)*
  • *Air Cooled CPUs with TDP over 205W only supported under specific conditions. Contact a Supermicro representative for details.
GPU
Max GPU Count
  • Up to 2 single-width GPU(s)
Supported GPU
  • Intel PCIe: Intel Data Center GPU Flex 140
  • NVIDIA PCIe: A2, L4
  • View GPU Options
System Memory
Memory
  • Slot Count: 16 DIMM slots
  • Max Memory (1DPC): Up to 4TB 3200MT/s ECC DDR4 RDIMM/LRDIMM
  • Supports Intel® Optane™ persistent memory 200 series
  • View Memory Options
Memory Voltage
  • 1.2V
On-Board Devices
SATA
  • SATA (6Gbps) ; RAID 0/1/5/10 support
NVMe
Chipset
  • Intel® C621A
Network Connectivity
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
Input / Output
LAN
  • 1 RJ45 1 GbE Dedicated IPMI LAN port(s)
USB
  • 2 USB 3.0 port(s) (rear)
  • 2 USB 2.0 port(s) (front)
Video
  • 1 VGA port(s)
Serial
  • 1 COM port(s) (Rear)
DOM
  • 1 SuperDOM (Disk on Module) port(s)
TPM
  • 1 TPM header
System BIOS
BIOS Type
  • AMI 32MB SPI FLASH ROM
Management
Software
Power configurations
  • ACPI/APM Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • System Lockdown
PC Health Monitoring
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory.
  • 8 Phase-switching voltage regulator
Chassis
Form Factor
  • 1U Rackmount
Model
  • CSE-LB16TS-R860AWP
Dimensions and Weight
Height
  • 1.7" (43 mm)
Width
  • 17.2" (437 mm)
Depth
  • 23.5" (597 mm)
Package
  • 7.7" (H) x 23.7" (W) x 31.8" (D)
Weight
  • Gross Weight: 40 lbs (18.14 kg)
  • Net Weight: 25 lbs (11.34 kg)
Available Color
  • Black
Front Panel
LED
  • Device Activity
  • LAN 1 Activity
  • LAN 2 Activity
  • Power status
  • System information
Buttons
  • Power On/Off 
  • UID button
Expansion Slots
PCI-Express (PCIe) Configuration
  • Default
    • 2 PCIe 4.0 x16 FHHL slot(s)
    • 2 PCIe 4.0 x16 AIOM slot(s) (OCP 3.0 compatible)
  • View AOC Options
Drive Bays / Storage
Drive Bays Configuration
  • Default: Total 10 bay(s)
    • 10 front hot-swap 2.5" NVMe*/SAS*/SATA drive bay(s)
  • (*NVMe/SAS support may require additional storage controller and/or cables, please see the optional parts list for details)
  • View Drive Options
M.2
  • 2 M.2 PCIe 3.0 x2 NVMe slot(s) (M-key 2280(default); VROC required for RAID)
  • View M.2 Options
System Cooling
Fans
  • 6x 4cm heavy duty fans with optimal fan speed control
Air Shroud
  • 2 Air Shroud(s)
Power Supply
800W/860WW Redundant Platinum Level Hot-plug power supplies
Note: SYS-120C-TN10R-EU (European) SKU uses PWS-861A-1R (Titanium Level)
Dimension (WxHxL)
  • 54.5 x 40.25 x 322 mm
+12V
  • Max: 66.6A / Min: 0A (100Vac-127Vac)
  • Max: 71.6A / Min: 0A (200Vdc-240Vdc)
  • Max: 71.6A / Min: 0A (200Vac-240Vac)
5V SB
  • Max: 4A / Min: 0A
AC Input
  • 800W: 100-127Vac / 50-60Hz
  • 860W: 200-240Vdc / 50-60Hz
  • 860W: 200-240Vac / 50-60Hz
Output Type
  • Backplanes (gold finger)
Operating Environment
ROHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature: -40°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity: 8% to 90% (Non-Condensing)
  • Non-operating Relative Humidity: 5% to 95% (Non-Condensing)
Resources & Downloads
Parts List
Standard Parts (Parts Included)
Part Number Qty Description
Motherboard / Chassis MBD-X12DDW-A6

CSE-LB16TS-R860AWP
1

1
Super X12DDW-A6 Motherboard

1U Chassis
Backplane BPN-SAS3-LB16A-N10 1 1U 10-Slot SFF Hybrid Backplane Supports 10xSAS3/SATA3/NVMe4 Storage Devices with 1x(2x4) + 2x(1x4) + 1x(2x2) Power Connectors
Cable CBL-SAST-1274LP-100 1 SlimlineLP x8 (LE) to 2x Slimline x4 (STR),68/76CM,100 O
CBL-SAST-1285LP-100 1 SlimlineLP x4 (STR) to Slimline x4 (STR),57CM,100 OHM,Ro
CBL-CDAT-0680-55 1 NCSI,2x10F to 2x10F,IDC,PH2.54,55cm,shield,28AWG,RoHS
CBL-PWCD-0160-IS 2 PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH
Fan FAN-0101L4 6 40x56,4 Pin PWM,Primary for SC809,111, Sec.for SC816,819,808
Parts MCP-150-00015-0B 6 Rubber pad, 3.0mm H, 10x10mm
MCP-160-00028-0B 1 Mylar Cable Channel for Cloud-DC, X12 DDW
MCP-320-00067-0B 1 Chassis base Air Foam block set (L+R) for Cloud-DC
Air Shroud MCP-310-00105-0B 2 Mylar Air Shroud for LA15-AW,LB13-AW,LB16-AW + X12DDW
Manual MNL-2332-QRG 1 120C-TN10R/120C-TN10R-EU Quick Reference Guide
Riser Card RSC-D-6G4 1 1U LHS DCO Riser card with one PCIe 4.0 x16 slot,HF,RoHS
RSC-DR-6G4 1 1U RHS DCO Riser card with one PCIe 4.0 x16 slot,HF,RoHS
Software SFT-OOB-LIC 1 License key for enabling OOB BIOS management
Heatsink / Retention SNK-P0077P 2 1U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms
*Power Supply PWS-860P-1R2 2 1U 860W, Redundant power supply, 54.5mm width, Platinum with
MCP-250-00009-0N 1 SC113 Redundant Power Distributor Cover
*Power Distributor PDB-PT116-SL8824 1 Based on PDB-PT116-L8824 to optimize 24Pin etc cable lengths
*Front Panel FPB-FP116 1 Front control board for SC116 (USB 2.0 x 2)
*Drive Tray(s) MCP-220-00188-0B 10 Black gen-5.5 tool-less cost-effective 2.5
*Rear Window MCP-240-00173-0N 1 1U X12 AWIO Rear window for LA15,LB16,LB13 Redundant PWS
*Rail Set MCP-290-00016-0N 1 1U open rack bracket set for CSE-PT51L,MCP-290-00054-0N
MCP-290-00063-0N 1set Rail set, quick/quick, default for 1U 17.2"W for SC113/SC116,RoHS/REACH
*Fan Holder MCP-320-00056-0B 24 40X56 rubber fan pin for SC819U, SC119U,RoHS/REACH
MCP-320-00066-0B 1 Fan holder with cable channel, 40X56mm fan, for LA15,LB16,LB13
MCP-340-00035-0B 2 Dummy fan 40x56mm for 40x56 counter-rotating fan (cost-effective)
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Optional Parts List
Part Number Qty Description
3108 CacheVault BTR-TFM8G-LSICVM02 1 CacheVault for Broadcom 3108 (requires a mount)
BTR-CV3108-1U1 1 CacheVault for Broadcom 3108 with mount for 1U 40 cm fan slot. (Note: It will replace one fan and lower overall system cooling)
3108 RAID Card CBL-SAST-1260-100 1 MiniSAS HD x8 (LE) to 2x Slimline x4 (STR) 60CM
AOC-S3108L-H8IR-16DD 1 Standard LP 8 internal ports (12Gb/s) Gen-3 16HDD RAID 0, 1, 5, 6, 10, 50, 60
3808 HBA Card CBL-SAST-1276F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
AOC-S3808L-L8IT 1 Standard LP 8 internal ports (12Gb/s) Gen-4 16HDD HBA
3816 HBA Card AOC-S3816L-L16IT 1 Standard LP 16 internal ports (12Gb/s) Gen-4 122HDD HBA
CBL-SAST-1276F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
CBL-SAST-1265F-100 1 Slimline x8 (STR) to Slimline x4 (STR) 64CM
3908 RAID Card CBL-SAST-1276F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
AOC-S3908L-H8IR-16DD 1 Standard LP 8 internal ports (12Gb/s) Gen-4 122HDD RAID 0, 1, 5, 6, 10, 50, 60
3908/3916 CacheVault BTR-CVPM05 1 CacheVault for Broadcom 3908/3916 (requires a mount)
3916 RAID Card CBL-SAST-1265F-100 1 Slimline x8 (STR) to Slimline x4 (STR) 64CM
AOC-S3916L-H16IR-32DD 1 Standard LP 16 internal ports (12Gb/s) Gen-4, 32HDD RAID 0, 1, 5, 6, 10, 50, 60
CBL-SAST-1276F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
AIOM Network Card(s) AOC-ATG-i2TM - OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X550-AT2
AOC-A25G-b2SM - OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Intel® E810-XXVAM2
AOC-ATG-i2T2SM - OCP 3.0 AIOM 4x 10GbE RJ45 & SFP+ PCIe x8 Intel® X710-TM4
AOC-A100G-b2CM - OCP 3.0 AIOM 2x 100GbE QSFP28 PCIe 4.0 x16 Broadcom® BCM57508
AOC-ATG-i2SM - OCP 3.0 AIOM 2x 10GbE SFP+ PCIe 3.0 x8 Intel® X710-BM2
AOC-ATG-b2TM - OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Broadcom® BCM57416
AOC-AG-i2M - OCP 3.0 AIOM 2x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM2
AOC-AH25G-m2S2TM - OCP 3.0 AIOM 2x 25GbE SFP28 & 2x 10GbE RJ45 PCIe x8/x4 Mellanox® CX4 Lx EN & Intel® X550-AT2
AOC-A25G-m2SM - OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Mellanox® CX-6 LX
AOC-ATGC-i2TM - OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X710-AT2
AOC-AG-i4SM - OCP 3.0 AIOM 4x 1GbE SFP PCIe 2.1 x4 Intel® i350-AM4
AOC-A25G-i4SM - OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1
AOC-ATG-i4SM - OCP 3.0 AIOM 4x 10GbE SFP+ PCIe 3.0 x8 Intel® XL710-BM1
AOC-AG-i4M - OCP 3.0 AIOM 4x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM4
AOC-A25G-i2SM - OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1
Cable Management Arm MCP-290-00152-0N 1 1U Supermicro Cable Management Arm 2nd Gen
CacheVault Mount MCP-240-21747-0N 1 CacheVault mounting card for AIOM slot
MCP-240-00203-0N 1 CacheVault mounting bracket for PCIe slot
MCP-240-00127-0N 1 CacheVault mounting tray for 2.5" drive bay
Fan Upgrade FAN-0163L4 6 40x40x56 mm 23.3K-20.3K RPM Counter-rotating Fan
Inlet Temp Sensor MCP-280-00033-0N 1 Universal Thermal sensor kit with 80cm I2C cable
License SFT-SDDC-SINGLE 1 Supermicro Data Center Monitor License
SFT-DCMS-SINGLE 1 Supermicro System Managment Software License
M.2 Tray AOC-SLG3-2SM2 - Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 SATA Modules RAID 0,1
AOC-SLG3-2NM2 - Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules RAID 0,1
AOC-SLG3-2M2 - Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules
AOC-SLG4-2H8M2 - Low Profile PCIe x8 add-on card supports 2 PCIe 4.0 x4 M-Key M.2 NVMe/SATA Modules RAID 0,1
NC-SI Cable CBL-PWEX-1099-34 1 FLAT IDC 2X11F/P1.27 TO IDC 2X11F/P1.27 NCSI 0.5A 35CM
NVMe Cable CBL-KIT-120C-TN10R-10 1 Enables 10 NVMe drive bays. Kit includes:
4x CBL-SAST-1219LP-85 (bay # 0-3, 6-9)
1x CBL-SAST-1234FLP-85 (bay # 4-5)
Power Supply Upgrade PWS-1K27A-1R 2 1200W Redundant Titanium Level Power Supply
TPM AOM-TPM-9672V-FIPS 1 SPI capable TPM 2.0 with Infineon 9672 controller w/ FIPS vertical form factor
AOM-TPM-9672V 1 SPI capable TPM 2.0 with Infineon 9672 controller vertical form factor
AOM-TPM-9670V-S-FIPS 1 SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS vertical form factor
AOM-TPM-9670V 1 SPI capable TPM 2.0 with Infineon 9670 controller vertical form factor
VROC HW Key AOC-VROCSTNMOD 1 Intel VROC Standard RAID 0, 1, 10
AOC-VROCPREMOD 1 Intel VROC Premium RAID 0, 1, 5, 10
CloudDC SuperServer SYS-120C-TN10R (Complete System Only )