SuperServer SYS-221HE-FTNR (Complete System Only)

SYS-221HE-FTNR Main SYS-221HE-FTNR Angle SYS-221HE-FTNR Top SYS-221HE-FTNR Front SYS-221HE-FTNR Rear
Integrated Board: X13DEM
Learn more

Key Applications

  • 5G Core and Edge
  • Telecom Micro Data Center
  • AI Inference and Machine Learning
  • Network Function Virtualization
  • Cloud Computing

Key Features

  1. Dual Socket E (LGA-4677) 4th Gen Intel® Xeon® Scalable processors
  2. 32 DIMM Slots; Up to 8TB: 32x 256GB DRAM
  3. 8 Configurable PCIe slots;
    Up to 8 PCIe 5.0 x8 or 4 PCIe 5.0 x16 slots with support for double-width GPU/Accelerator cards
  4. Flexible networking options with 2 AIOM networking slots (OCP NIC 3.0 compatible)
  5. 6x 2.5" hot-swap NVMe/SATA/SAS drive bays
  6. 6 heavy duty hot-swap fans with optimal fan speed control
  7. Redundant 2000W AC Platinum level power supplies
...
...
Specifications Resources Parts List
Specifications
Product SKUs
SuperServer SYS-221HE-FTNR (Silver)
Motherboard
Super X13DEM
Processor
CPU
Core Count
  • Up to 60C/120T; Up to 112.5MB Cache per CPU
Note
  • Supports up to 350W TDP CPUs (Air Cooled)
GPU
Max GPU Count
  • Up to 3 double-width or 1 single-width GPU(s)
Supported GPU
  • Intel PCIe: Intel Data Center GPU Flex 170
  • NVIDIA PCIe: H100,L40S,A40,L40,A10
  • View Complete List
CPU-GPU Interconnect
  • PCIe 5.0 x16 CPU-to-GPU Interconnect
GPU-GPU Interconnect
  • PCIe
System Memory
Memory
  • Memory Capacity: 32 DIMM slots
  • Up to 8TB: RDIMM
  • Memory Type: 4800MHz ECC DDR5 RDIMM
Memory Voltage
  • 1.1 V
Error Detection
  • ECC
On-Board Devices
SATA
  • SATA3 (6Gbps); RAID 0/1/5/10 support
NVMe
  • NVMe; RAID 0/1/5/10 support (Intel® VROC RAID Key required)
Chipset
  • Intel® C741
Network Connectivity
  • 2x 25GbE SFP28 with Broadcom® BCM57414 (optional)
  • 2x 100GbE QSFP28 with Broadcom® BCM57508 (optional)
  • 2x 100GbE QSFP28 with Intel® E810-CAM2 (optional)
  • 2x 100GbE QSFP28 or 4x 10GbE SFP+ with Intel® X710-BM2 (optional)
  • 2x 200GbE QSFP56 with Mellanox® CX-6 VPI (optional)
  • 2x 100GbE QSFP56 with Mellanox® CX-6 DX (optional)
  • 2x 1GbE BaseT with Intel® I350-AM2 (optional)
  • 4x 10GbE RJ45/SFP+ with Intel® X710-TM4 (optional)
  • 1x 400GbE OSFP with NVIDIA® CX-7 NDR (optional)
  • 4x 10GbE BaseT with Intel® X550 (optional)
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
Input / Output
LAN
  • 1 RJ45 Dedicated BMC LAN port
USB
  • 2 USB 2.0 port(s) (2 front)
Video
  • 1 VGA port(s)
System BIOS
BIOS Type
  • AMI 256MB SPI Flash
Management
Software
Power Configurations
  • ACPI Power Management
  • Power-on mode for AC power recovery
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • Supply Chain Security: Remote Attestation
  • Runtime BMC Protections
  • System Lockdown
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory
FAN
  • Fans with tachometer monitoring
  • Pulse Width Modulated (PWM) fan connectors
  • Status monitor for speed control
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-HE211-R000NFP
Note
  • Standard sliding rail kit: Post to Post 19.1" ~ 26.4“
Dimensions and Weight
Height
  • 3.5" (88.9mm)
Width
  • 17.2" (436.88mm)
Depth
  • 22.6" (574mm)
Package
  • 9.7" (H) x 23.5" (W) x 36.9" (D)
Weight
  • Net Weight: 34.4 lbs (15.6 kg)
  • Gross Weight: 47.4 lbs (21.5 kg)
Available Color
  • Silver
Front Panel
Buttons
  • Power On/Off 
  • UID button
LEDs
  • HDD activity LED
  • LAN1 activity
  • LAN2 activity
  • Power Fail
  • Power status LED
  • System information
Expansion Slots
PCI-Express (PCIe)
  • 3 PCIe 5.0 x16 or x8 FHFL slot(s)
  • 3 (Optional) PCIe 5.0 x8 FHFL slot(s)
  • 1 PCIe 5.0 x8 or (Optional) x16 FHHL slot(s)
  • 1 PCIe 5.0 x8 FHHL or Disable slot(s)
Note
  • If Slot 1 is configured as PCIe x16, Slot 2 will be disabled; If Slot 3 is configured as PCIe x16, Slot 4 will be disabled; If Slot 5 is configured as PCIe x16, Slot 6 will be disabled; (Optional) If Slot 7 is configured as PCIe x16, Slot 8 will be disabled.
Drive Bays / Storage
Hot-swap
  • 6x 2.5" hot-swap NVMe/SATA/SAS drive bays (6x 2.5" NVMe hybrid) (SAS support requires additional parts. Please see the Optional Parts list.)
M.2
  • 2 M.2 NVMe OR 2 M.2 SATA3
  • M-Key, 2280/22110
System Cooling
Fans
  • 6 Counter-rotating, Hot-swappable 6cm Fan(s)
Liquid Cooling
  • Direct to Chip (D2C) Cold Plate (optional)
Power Supply
2x 2000W Redundant Titanium (certification pending) Level power supplies
Dimension

(W x H x L)
  • 73.5 x 40 x 203 mm
AC Input
  • 1000W: 100-127Vac / 50-60Hz
  • 1800W: 200-220Vac / 50-60Hz
  • 1980W: 220-230Vac / 50-60Hz
  • 2000W: 220-240Vac / 50-60Hz (for UL only)
  • 2000W: 230-240Vac / 50-60Hz
  • 2000W: 230-240Vdc / 50-60Hz (for China only)
+12V
  • Max: 83A (100Vac-127Vac)
  • Max: 150A (200Vac-220Vac)
  • Max: 165A (220Vac-230Vac)
  • Max: 166A (230Vac-240Vac)
12V SB
  • Max: 3.5A
Output Type
  • Backplanes (gold finger)
Certification 94%+   Titanium (certification pending) Level

 


  [ Test Report ]
Operating Environment
Environmental Spec.
  • Operating Temperature:
       0°C ~ 35°C (32°F ~ 95°F)
  • Non-operating Temperature:
       -40°C to 70°C (-40°F to 158°F)
  • Operating Relative Humidity:
       8% to 90% (non-condensing)
  • Non-operating Relative Humidity:
       5% to 95% (non-condensing)


Resources
Parts List
Standard Parts (Parts Included)
Part Number Qty Description
Motherboard / Chassis MBD-X13DEM

CSE-HE211-R000NFP
1

1
Super X13DEM Motherboard

2U Chassis
Add-on Card / Module AOM-AIOM-2X8-G5-P 1 AIOM adaptor board (cable solution), PCIe Gen-5,RoHS
AOM-HE211-AIOM-X13-P 1 AIOM extension board for Hyper-E 2U, X13 MB,RoHS
AOM-HS119-IO-P 1 Hyper IO Board,RoHS
Backplane BPN-NVME5-HE211N-S6 1 1U 6-port all hybrids backplane support up to 6x SAS3/SATA3/NVME5 storage devices
Cable CBL-GNZ4-1227M5YRR16 1 (GENZ 4C STR to 2 MCIO) x8 RA/RA 27/16cm,30#,RoHS
CBL-MCIO-1213M5 2 [NR] MCIO x8 (STR to STR),13cm,85OHM,RoHS
CBL-MCIO-1224AM5 2 [NR] MCIO (x8 STR to x8 STR), 24CM, LNRV, G5, 85OHM, RoHS
CBL-MCIO-1230M5 1 [NR] MCIO x8 (STR to STR),30CM,85OHM,RoHS
CBL-MCIO-1233M5R 1 MCIO x8 (STR to RA),33cm,85OHM,RoHS
CBL-PWEX-1136YVB-45 1 (2x4 to 3 2x2), PH3.0,45cm,8.5A/p,18AWG,RoHS
CBL-SAST-1243LP-85 1 SlimlineLP x8 (STR to STR),INT,30CM,85 OHM,RoHS
CBL-SAST-1249LP-85 1 SlimlineLP x8 (STR) tp 2x SlimlineLP x4 (STR),49/61CM,8
CBL-OTHR-1117 OR 1 [NR] 2x15,PH1.0 to 2x15,PH1.0,28AWG,30CM,1A/pin,RoHS
CBL-CDAT-1060-30 2x15,PH1.0 to 2x15,PH1.0,28AWG,30CM,1A/pin,RoHS
CBL-MCIO-1218M5 OR 2 MCIO x8 (STR to STR),18CM,85OHM,RoHS
CBL-MCIO-1218M5-1 MCIO x8 (STR to STR),18CM,85OHM,RoHS
CBL-MCIO-1230M5R OR 1 MCIO x8 (STR to RA),30CM,85OHM,RoHS
CBL-MCIO-1230M5R-1 [NR] MCIO x8 (STR to RA),30CM,85OHM,RoHS
CBL-PWEX-1142-40 OR 1 MicroHi,(2x4 to 2x4),PH3.0,40CM,8A/pin,18AWG,RoHS
CBL-PWEX-1142B-40 MicroHi(2x4 to 2x4), PH3.0, 40cm, 8.5A/p, 18AWG, RoHS
CBL-CDAT-1290F 1 [NR] FRONT CNTL,20 TO 20 PIN,P0.5,FLAT,90CM,STD,RoHS
CBL-PWCD-0160-IS 2 PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH
CBL-PWEX-1104-8 1 [NR] 2x4,PH3.0,M to 2x3,PH2.0,F,3A/pin,22AWG,8CM
Fan FAN-0215L4 6 60x60x56 mm, 17K-17K RPM, Counter-rotating Cooling Fan for 2U Hyper-E (CSE-HE211) Series Servers
Air Shroud MCP-310-21106-0B 4 HE211 Mylar air shroud for X12DHM 8-Barlow Pass Memory,RoHS
Power Supply PWS-2K08F-1R 2 1U 2000W 100-240VAC/50-60Hz, reverse airlfow
Riser Card RSC-H-68G5 2 1U LHS Hyper Riser card with one PCIe 5.0 X16 and one P
RSC-H2-6888G5S 1 2U LHS Hyper Riser card with one PCIe 5.0 X16 and thre
Software SFT-OOB-LIC 1 License key for enabling OOB BIOS management
Heatsink / Retention SNK-P0088PR 2 2U Proprietary Passive CPU Heat Sink for X13 Generation Hyper-E Series Servers
*Front Panel FPB-FP826-T 1 Chassis front control board for SC826
*Drive Tray(s) MCP-220-00178-0B 6 2.5 thin profile drive tray, Orange tab (for hotswap NVMe drive), for SC119UH
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Optional Parts List
Part Number Qty Description
Cable CBL-PWEX-1148-30 1 CPU 8-pin connector power cable for GPU installed on PCIe slot 5
CBL-PWEX-1172-2654 1 CPU 8-pin connector power cable for GPU installed on PCIe slot 1 and PCIe slot 3
CBL-PWEX-1171-2654 1 PCIe 8-pin connector power cable for GPU
CBL-PWEX-0962Y-30 1 Power cable for H100 GPU installed on PCIe Slot 3
CBL-PWEX-0962Y-20 1 Power cable for H100 GPU installed on PCIe Slot 1 and PCIe Slot 5
CBL-MCIO-1232M5 1 Optional cable for PCIe Slot 1 5.0 x8/ PCIe Slot 2 5.0 x8
CBL-GNZ4-1227M5YR21 1 Optional cable for PCIe Slot 3 5.0 x8/ PCIe Slot 4 5.0 x8
Optional sliding rail kit MCP-290-11902-0N  1 Optional sliding rail kit for Post to Post: 24" ~ 35.3"
MCP-290-11903-0N  1 30.5" ball-bearing rail set, without auto latch for Hyper 1U & 2U Project
MCP-290-11901-0N  1 Optional sliding rail kit for Post to Post: 26.5" ~ 41.2"
Riser Card RSC-H2-668G5S 1 Optional Riser Card for PCIe Slot 7 5.0 x16/ PCIe Slot 8 disable
IoT SuperServer SYS-221HE-FTNR (Complete System Only ) New
  1. Products
  2. Systems
  3. IoT
  4. SYS-221HE-FTNR