Question |
SuperServer 6028U-TRT+ with 2x E5-2620 V4 CPUs: Upon startup, Server logo appears followed by error message indicating "Failing DIMM: DIMM location (Uncorrectable memory component found) P1-DIMMA1, P2-DIMME1"--Server reports failing DIMMs in new server build. |
|
Answer |
Please try update the BIOS to 2.0b with v3 CPU. After that, you may use the v4 CPU. |
|
|
FAQ Stats |
FAQ ID |
Related Category / Keyword |
Date Posted |
Code |
25325 |
N/A
|
03/31/17 |
|
Print Answer
|