Question
We need firmware for the backplane BPN-SAS3-216EL1/216EL12 and need assistance using flash tool to update firmware/mfg in Linux CLI.
Answer
Sample Commands for your reference. 

_Please download
"CLIXTL" utility at below link.<o:p></o:p>

_https://www.supermicro.com/wdl/utility/ExpanderXtools_Lite/Linux/CLIXTL6.10.C_Linux.zip







_1.Find out each
expander chip information:

>CLIXTL –i –t <backplane SAS Address>



2.Flash FW on target expander chip on all region:


>CLIXTL -f all -t <backplane
SAS Address> -d </directory /*.fw>



3.Flash MFG file on target expander chip:

>CLIXTL -c -t <backplane SAS Address>
-d </directory /*.bin><o:p></o:p>