Question
We recently purchased a SSG-640SP-ECCR36H for additional data storage servers.  We have been using SSG-6048R-E1CR36H running OpenE DSS V7 for over a decade.  We are also in the process of moving into SecureBoot.  However, after OS installation, the OpenE DSS 7.0 cannot see the VD created through MegaRAID AOC-S3908L-H8iR.  Can you help?
Print
Answer
SSG-640SP-E1CR36H came with AOC-S3908L-H8iR.  The old OpenE DSS v7 inbox megaraid driver does not support the AOC-S3908L-H8iR. Your alternative solution is to use AOC-S3108L-H8iR and also replace the SAS cable.

Mini SAS HD - Mini SAS HD cable
https://store.supermicro.com/us_en/supermicro-minisas-hd-to-minisas-hd-80cm-cable-cbl-sast-0531.html?srsltid=AfmBOoqRCx6W8vvxm9ZjiVQ-0CE9c4x_J47Sx9kAW6WX5nBXWq4GgZrO
Was this FAQ helpful?
Enter Comments Below: