SuperStorage 6048R-E1CR45H (Complete System Only)

  Products  Systems   SuperStorage   [ 6048R-E1CR45H ]





Integrated Board
Super X10DSC+
Key Features
1. Dual socket R3 (LGA 2011) supports
    Intel® Xeon® processor E5-2600
    v4/ v3 family (up to 160W TDP)
2. Up to 3TB ECC 3DS LRDIMM , up to
    DDR4- 2400MHz ; 24 DIMM slots
3. 2 PCI-E 3.0 x16, 1 PCI-E 3.0 x8
4. SIOM for flexible networking options
5. 45 Hot-swap 3.5" SAS3/SATA3 drive
    bays; 2 rear Hot-swap 2.5" SATA
    drive bays; optional 6 NVMe bays
6. Broadcom 3108 SAS3, HW RAID
7. Server remote management: IPMI 2.0
    / KVM over LAN / Media over LAN
8. 5 hot-swap 8cm redundant PWM fans
    PWM fans
9. 1600W Redundant Power Supplies
    Platinum Level (94%+) Certified
10. Front 3.5" LCD display
    Supermicro 90-Bay Storage

Complete System Only: To maintain quality and integrity, this product is sold only as a completely-assembled system (with minimum 2 CPUs, 2 DIMMs, 12 HDDs and 1 NIC or SIOM card).

 Drivers & Utilities   BIOS   IPMI   Tested Memory  NVMe Options   Manuals    OS Certification Matrix    Drive Options   Tested SIOM

Product SKUs - Discontinued SKU (EOL). Please contact sales-rep for alternative options.
SSG-6048R-E1CR45H
  • SuperStorage 6048R-E1CR45H (Black)
 
Motherboard

Super X10DSC+
 
Processor/Cache
CPU
  • Intel® Xeon® processor E5-2600 v4/ v3 family (up to 145W TDP) *
  • Dual Socket R3 (LGA 2011)
Cores / Cache
  • Up to 22 Cores / Up to 55MB Cache
System Bus
  • QPI up to 9.6 GT/s
Note BIOS version 2.0 or above is required
Note * Please contact Supermicro Technical Support for additional information about frequency optimized CPUs and specialized system optimization.
 
System Memory
Memory Capacity
  • 24x 288-pin DDR4 DIMM slots
  • Up to 3TB ECC 3DS LRDIMM, 768 ECC RDIMM
Memory Type
  • 2400/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit
DIMM Sizes
  • RDIMM: 32GB, 16GB, 8GB, 4GB
  • LRDIMM: 64GB, 32GB
  • 3DS LRDIMM: 128GB
Memory Voltage
  • 1.2 V
Error Detection
  • Corrects single-bit errors
 
On-Board Devices
Chipset
  • Intel® C612 chipset
SAS
  • Broadcom 3108 SAS3, HW RAID
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
  • ASPEED AST2400 BMC
Network Controllers
  • SIOM support for flexible networking options
Graphics
  • ASPEED AST2400 BMC
 
Input / Output
USB
  • 3 USB 3.0 ports (2 rear + 1 Type A)
VGA
  • 1 VGA port
Serial Port / Header
  • 1 Fast UART 16550 port / 1 Header
Chassis
Form Factor
  • 4U Rackmount
Model
  • CSE-946LTS-R1K66P
 
Dimensions and Weight
Width
  • 17.2" (437mm)
Height
  • 7" (178mm)
Depth
  • 26" (660mm)
Available Colors
  • Black
 
Front Panel
Buttons
  • Power On/Off button
  • System Reset button
LEDs
  • Power status LED
  • Hard drive activity LED
  • 2 Network activity LEDs
  • System Information LED
  • Power fail LED
LCD
  • 3.5" TFT LCD panel
  • Full-Color display with 320x480 pixels
  • Real-time system status from IPMI
  • Easy read graphical User Interface
 
Expansion Slots
PCI-Express
  • 2 PCI-E 3.0 x16 slots
  • 1 PCI-E 3.0 x8 slot
 
Drive Bays
Hot-swap
  • 45 Hot-swap 3.5" SAS3/SATA3 drive bays
  • 2 Rear Hot-swap 2.5" SATA drive bays
Optional
  • 6 NVMe bays (optional)
 
Backplane
SAS3/SATA3 single expander per backplane
 
System Cooling
Fans
  • 5 Hot-swap 80mm rear exhaust cooling fans
  • Redundant cooling
 
Power Supply
1600W 1U Redundant Power Supplies with PMBus
Total Output Power
  • 1000W: 100 – 127Vac
  • 1600W: 200 – 240Vac
Dimension
(W x H x L)
  • 73.5 x 40 x 265 mm
Input
  • 100-127Vac / 12.9A Max / 50-60Hz
  • 200-240Vac / 9.5A Max / 50-60Hz
+12V
  • Max: 82A / Min: 0.1A (100-127Vac)
  • Max: 132A / Min: 0.1A (200-240Vac)
12V SB
  • Max: 2A / Min: 0.2A
Output Type
  • 25 Pairs Gold Finger Connector
Certification Platinum Level Certified94%+  Platinum Level
  [ Test Report ]
 
System BIOS
BIOS Type
  • 128Mb SPI Flash EEPROM with AMI BIOS
BIOS Features
  • Plug and Play (PnP)
  • APM 1.2
  • PCI 2.2
  • ACPI 1.0 / 2.0
  • USB Keyboard support
  • SMBIOS 2.3
  • UEFI
 
Operating Environment / Compliance
RoHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature:
       10°C to 35°C (50°F to 95°F)
  • Non-operating Temperature:
       -40°C to 70°C (-40°F to 158°F)
  • Operating Relative Humidity:
       8% to 90% (non-condensing)
  • Non-operating Relative Humidity:
       5% to 95% (non-condensing)
See Parts List

Parts List - (Items Included)
 
Part Number
Qty
Description
Motherboard / Chassis MBD-X10DSC+
CSE-946LTS-R1K66P
1
1
Super X10DSC+ Motherboard
4U Chassis
Rear Window MCP-240-94601-0N - SC946S rear window w/ 3x LP slots for X10DSC+
Rear Window MCP-290-00132-0N - SIOM dummy cover for 226S/826S/946S
Add-on Card / Module AOM-S3108M-H8L-P 1 sas3 roc mez for X10dsc
Backplane BPN-SAS3-826TQ-B2B 1 2-port 2U SAS3 12Gbps backplane, support up to 2x 2.5-inch SAS3/SATA3 HDD/SSD
Backplane BPN-SAS3-946LEL1 1 45-port 4U SC946L Top-load SAS3 12Gbps expander backplane, support up to 45x 3.5-inch SAS3/SATA3 HDD/SSD
Cable 1 CBL-0481L 2 SATA,INT,ROUND,ST-ST,81CM,30AWG
Cable 2 CBL-CDAT-0728 1 4 Pin to 4 Pin I2C cable, 65cm, 26AWG, 4 wires, pinout 1-1, for vpp header(jnvi2c1),RoHS/REACH
Cable 3 CBL-PWCD-0578 2 PWCD,US,IEC60320 C14 TO C13,3FT,14AWG
Cable 4 CBL-PWEX-0862 1 Powerlug to 5.7 Radsok, black 12AWG, 53cm for SC946S
Cable 5 CBL-PWEX-0863 1 Powerlug to 5.7 Radsok, yel 12AWG, 32cm for SC946S
Cable 6 CBL-PWEX-1024 1 Powerlug to 5.7 Radsok, black 12AWG, 45cm,RoHS
Cable 7 CBL-SAST-1006-1 2 SLIMLINE SAS3, INT, 50CM 32AWG,RoHS
Heatsink / Retention SNK-P0048PS 2 2U Passive CPU Heat Sink for X9, X10 Generation Systems Equipped w/ a Narrow ILM MB
* Power Supply PWS-1K66P-1R 2 1U 1600W Redundant Platinum Power Supply 73.5mm width,RoHS/REACH,PBF
* Power Distributor PDB-PT946S-824 1 standard 24pin output
* Cable 8 CBL-0087 1 CBL,FRONT CNTL,16 TO 16 PIN,Ribbon,50CM
* Cable 9 CBL-0160L 2 NEMA5-15P to C13 US power cord 16AWG 6ft, PBF (default for high watt)
* Cable 10 CBL-0303L 1 4 pin to 4 pin power cable, S-RA, 40CM. 20AWG
* Cable 11 CBL-0459L 2 LATCH CLAMP,AC POWER CORD
* Cable 12 CBL-0481L 2 SATA,INT,ROUND,ST-ST,81CM,30AWG
* Cable 13 CBL-CDAT-0841 1 8 pin to 8 pin round SGPIO cable, 81cm, 28AWG, pinout 1-1
* FAN 1 FAN-0184L4 5 80x80x38 mm, 14.4K RPM, Rear Exhaust Fan for SC946S Chassis (60-bay)
* Front Panel FPB-FP829H 1 Front Control Board for SC829H chassis
* Drive Tray(s) MCP-220-00117-0B 2 Black gen-3 hot-swap tool-less 2.5- inch HDD tray
* Drive Tray(s) MCP-220-94601-0N 45 SC946ED 3.5\" / 2.5\" tool-less HDD tray
* Rail Set MCP-290-00150-0N 1 Rail set, Auto-latch, quick/quick, default 4U 17.2
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.


Optional Parts List
  Part Number Qty Description
3108 Cache Protection BTR-CV3108-U1 - Broadcom 3108 CacheVault kit (ROHS, Reach)
NVME kit (Full kit needed) AOC-SLG3-2E4R
MCP-220-94607-0N
CBL-SAST-0818
CBL-SAST-0850
1
1
4
2
NVMe AOC
SC946S NVMe kits w/ cage, tray, cable, BPN (no NVMe cable)OCuLink v.91,INT,PCIe NVMe SSD, 55CM,34AWG
OCuLink to MiniSAS HD V.91, INT, PCIe NVMe SSD, 37CM, 15D15F7D, 34AWG
Global Services & Support OS4HR3/2/1
OSNBD3/2/1
-
-
3/2/1-year onsite 24x7x4 service
3/2/1-year onsite NBD service
Software SFT-OOB-LIC 1 OOB Management Package (per node license)
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)
SIOM Network Card(s) AOC-MGP-I2
AOC-MGP-I4
AOC-MTG-I2T
AOC-MTG-I4T
AOC-MTGN-I2S
AOC-MTG-I4S
-
-
-
-
-
-
SIOM 2-port GbE, Intel i350-AM2
SIOM 4-port GbE, Intel i350-AM4
SIOM 2-port 10GBase-T, Intel X550
SIOM 4-port 10GBase-T, Intel X550
SIOM 2-port 10G SFP+, Intel 82599ES
SIOM 4-port 10G SFP+, Intel XL710
Hide Parts List

Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.