SuperServer SYS-620BT-DNTR (Complete System Only)

2U 2-node BigTwin with 6 3.5" NVMe/SATA bays per node

SYS-620BT-DNTR Main SYS-620BT-DNTR Angle SYS-620BT-DNTR Node SYS-620BT-DNTR Front SYS-620BT-DNTR Rear
Integrated Board: X12DPT-B6
Learn more

Key Applications

  • Hyperconverged Infrastructure
  • Scale-Out Object Storage
  • Back-up & Recovery

Key Features

Two hot-pluggable systems (nodes) in a 2U form factor. Each node supports the following:
  1. Socket P+ (LGA 4189) support 3rd Gen Intel® Xeon® Scalable processors
  2. Intel® C621A
  3. 20 DIMM Slots (16 DIMM Slots + 4 Intel® Optane™ Persistent Memory Slots)
  4. Optional 2U Riser for Slot 1, CPU1 x16 PCIe 4.0 (RSC-P2R-6G4)
    1 PCIe 4.0 x16 (LP) slot;
    2 PCIe 4.0 x8 (LP) slot;
    Tool-less support
    Optional HW RAID Boot Controller via AOC-SMG3-2M2-B (NVMe Only)
    Internal PCIe 3.0 for 2 x4 M.2 NVMe/SATA support onboard (22x110 supported on slot2))
  5. Network connectivity via AIOM (OCP 3.0 compliant)
  6. 6 Hot-swap 3.5" drive bays; 6 PCIe 4.0 NVMe/SATA 3.5" drives
  7. 2 cooling fans per node, 14.9K RPM
  8. 2200W Redundant Power Supplies Titanium Level (96%+); Shared Power Design
...
...
Specifications Resources & Downloads Parts List
Specifications
Product SKUs
SuperServer SYS-620BT-DNTR
Motherboard
Super X12DPT-B6
Processor (per Node)
CPU
  • Dual Socket P+ (LGA-4189)
  • 3rd Gen Intel® Xeon® Scalable processors
Core Count
  • Up to 36C/72T; Up to 54MB Cache per CPU
Note
  • Supports up to 250W TDP CPUs (Air Cooled)
GPU (per Node)
Max GPU Count
  • Up to 1 double-width GPU(s)
System Memory (per Node)
Memory
  • Slot Count: 16 DIMM slots
  • Max Memory (2DPC): Up to 4TB 3200MT/s ECC DDR4 RDIMM
  • Supports Intel® Optane™ persistent memory 200 series
  • View Memory Options
On-Board Devices (per Node)
Chipset
  • Intel® C621A
Network Connectivity
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
NVMe
Input / Output (per Node)
LAN
  • 1 RJ45 1 GbE Dedicated BMC LAN port(s)
USB
  • 2 USB 3.0 Type-A port(s) (Rear)
Video
  • 1 VGA port(s)
System BIOS
BIOS Type
  • AMI 32MB Flash ROM
Management
Software
Power configurations
  • ACPI / APM Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • System Lockdown
PC Health Monitoring
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory.
  • 7+1 Phase-switching voltage regulator
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-827BD-000NP
Dimensions and Weight
Height
  • 3.47" (88 mm)
Width
  • 17.68" (449 mm)
Depth
  • 30.5" (774 mm)
Package
  • 9.76" (H) x 24.65" (W) x 45.28" (D)
Weight
  • Gross Weight: 80.7 lbs (36.6 kg)
  • Net Weight: 55.1 lbs (25 kg)
Available Color
  • Black
Front Panel
LED
  • HDD activity LED
  • Network activity LEDs
  • Power status LED
  • Universal Information (UID) LED
Buttons
  • Power On/Off button
  • UID button
Expansion Slots (per Node)
PCI-Express (PCIe) Configuration
Drive Bays / Storage (per Node)
Drive Bays Configuration
  • Default: Total 6 bay(s)
    • 6 front hot-swap 3.5" PCIe 4.0 NVMe/SATA drive bay(s)
  • View Drive Options
M.2
  • 2 M.2 PCIe 3.0 x4 NVMe/SATA slot(s) (M-key 2280(default)/22110; VROC required for RAID)
  • View M.2 Options
System Cooling
Fans
  • 4x 14.9K RPM Heavy Duty 8cm Fan(s)
Power Supply
2200W Redundant Titanium Level power supplies
Dimension (WxHxL)
  • 45 x 40 x 480 mm
+12V
  • Max: 100A / Min: 0A (100Vac-127Vac) (for TUV/CB/others safety rating only)
  • Max: 174.17A / Min: 0A (180Vac-220Vac) (for UL/cUL safety rating only)
  • Max: 150A / Min: 0A (200Vac-220Vac) (for TUV/CB/others safety rating only)
  • Max: 165A / Min: 0A (220Vac-230Vac) (for TUV/CB/others safety rating only)
  • Max: 183.33A / Min: 0A (220Vac-240Vac) (for UL/cUL safety rating only)
  • Max: 174.17A / Min: 0A (230Vdc-240Vdc) (for CQC safety rating only)
  • Max: 174.17A / Min: 0A (230Vac-240Vac) (for TUV/CB/others safety rating only)
12V SB
  • Max: 2.1A / Min: 0A
AC Input
  • 1200W: 100-127Vac / 50-60Hz
  • 2090W: 180-220Vac / 50-60Hz (for UL/cUL safety rating only)
  • 1800W: 200-220Vac / 50-60Hz (for TUV/CB/others safety rating only)
  • 1980W: 220-230Vac / 50-60Hz (for TUV/CB/others safety rating only)
  • 2200W: 220-240Vac / 50-60Hz (for UL/cUL safety rating only)
  • 2090W: 230-240Vdc / 50-60Hz (for CQC safety rating only)
  • 2090W: 230-240Vac / 50-60Hz (for TUV/CB/others safety rating only)
Output Type
  • Backplanes (connector)
Operating Environment
ROHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature: -40°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity: 8% to 90% (Non-Condensing)
  • Non-operating Relative Humidity: 5% to 95% (Non-Condensing)
Resources & Downloads
Parts List
Standard Parts (Parts Included)
Part Number Qty Description
Motherboard / Chassis MBD-X12DPT-B6

CSE-827BD-000NP
2

1
Super X12DPT-B6 Motherboard

2U Chassis
Add-on Card / Module AOC-SMG3-2H8M2-BW-P 2 2x Hybrid M.2 riser carrier card for X12 BigTwin,RoHS
Backplane BPN-NVME4-827BHQ-S3 1 2U 12-Port 4-Node All-Hybrid BT BPN for 3xNVMe4/SAS4/SATA3 Medias per Node
Cable CBL-SAST-1243-100 2 Slimline X8 (STR) to Slimline X8 (STR), 41.5CM,100 OHM
CBL-PWCD-0578-1 OR 2 PWCD,US,IEC60320 C14 TO C13,3FT,14AWG,RoHS
CBL-PWCD-0578-IS PWCD,US,IEC60320 C14 TO C13,910mm,14AWG,15A,250V,Black, RoHS
Drive Tray(s) MCP-220-00133-0B-BULK 12 Black gen 8 hot-swap 3.5
Air Shroud MCP-310-21731-0B 2 BigTwin 2U2N plastic air shroud for X12DPT-B
Riser Card RSC-P2R-88G4 2 2U RHS TwinPro Riser card with twoPCI-E4.0x8slots,HF,RoH
Storage Controller Card SCC-F6N6T-B2 2 2U SCC with 6x NVMe, 6x SATA for BigTwin X12,HF
Software SFT-OOB-LIC 2 License key for enabling OOB BIOS management
Heatsink / Retention SNK-P0078PW 2 2U Passive Wide CPU Heatsink (92x113x65mm) for X12 ICX/CPX CPU, Heatpipe
SNK-P0079P 2 1.5U Passive 55H mm CPU HS for X12 Whitley and Cedar Island
*Power Supply PWS-2K22A-1R 2 1U 1200W/2200W Redundant Titanium BigTwin w/PMBus power supply, W45xH40xL480 mm, C14 inlet
*Power Distributor PDB-PT217-BGTWN 1 2U Big Twin Power Distributor Board Support Redundant 2KW
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Optional Parts List
Part Number Qty Description
2U Riser for Slot 1, CPU1 x16 PCIe 4.0 RSC-P2R-6G4 - expansion slots
3.5-to-2.5" HDD Conversion Tray MCP-220-00140-0B - Black gen 8 hot-swap 3.5-to-2.5 Tool-less HDD tray, orange tab (Qty as Needed)
CacheVault for RAID Controller BTR-CVPM05
BKT-BBU-BRACKET-05
- Broadcom CacheVault
Mounting Bracket
M.2 NVMe RAID Controller AOC-SMG3-2M2-B-P - 2x M.2 NVMe RAID Controller Card, x8 Gen3
SAS3908 RAID Controller AOC-S3908L-H8iR-16DD
CBL-SAST-1234F-100
1 SAS3908 HW RAID Controller 12Gb/s SAS, x8 Gen4 (Qty per Node)
Slimline x8 (STR) to Slimline x8 (STR) for 8 drives support
SPI Capable TPM Options AOM-TPM-9670H-FIPS 1 SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor, Supporting FIPS 140-2 (Qty per Node)
AOM-TPM-9671H-S 1 SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor (Qty per Node)
AOM-TPM-9670H-S 1 SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor (Qty per Node)
SuperCloud Composer License SFT-SDDC-SINGLE - SDDC Monitor License - Single License per Monitored host
System Management Suite SFT-DCMS-Single - Supermicro System Management Software Suite node
VROC Options AOC-VROCPREMOD 1 Intel VROC Premium, RAID 0, 1, 5, 10 (Qty per Node)
AOC-VROCSTNMOD 1 Intel VROC Standard, RAID 0, 1, 10 (Qty per Node)
BigTwin SuperServer SYS-620BT-DNTR (Complete System Only )