SuperServer SYS-240P-TNRT (Complete System Only)

2U 4-socket system with 48 DIMMs and 24 NVMe/SAS/SATA drive bays

Key Applications

  • Artificial Intelligence (AI)
  • Business Intelligence
  • ERP, CRM
  • Scientific Virtualization
  • In-Memory Database
  • HCI
  • SAP HANA

Key Features

  1. Quad Socket P+ (LGA-4189) 3rd Generation Intel® Xeon® Scalable processors
  2. 48 DIMMs; Up to 18TB 3DS ECC DDR4-3200:LRDIMM/RDIMM/Intel® Intel® DCPMM
  3. Intel® Ethernet Controller X710-TM4 2x 10G RJ45 + 2x 10G SFP+ port; (optional) AIOM up to 100G QSFP28
  4. Up to 24 Hot-swap 2.5" NVMe/SAS3/SATA3 drive bays (Default with 8 SAS3/SATA3 drive bays); Onboard 2x M.2 SATA.
  5. 4 heavy duty fans w/ optimal fan speed control; 1 Air Shroud
...
...
Specifications Resources & Downloads Parts List
Specifications
Product SKUs
SuperServer SYS-240P-TNRT
Motherboard
Super X12QCH+
Processor
CPU
  • Quad Socket P+ (LGA-4189)
  • 3rd Gen Intel® Xeon® Scalable processors
Core Count
  • Up to 28C/56T; Up to 38.5MB Cache per CPU
Note
  • Supports 120W - 250W TDP CPUs (Air Cooled)
GPU
Max GPU Count
  • Up to 2 double-width or 2 single-width GPU(s)
Supported GPU
System Memory
Memory
  • Slot Count: 48 DIMM slots
  • Max Memory (2DPC): Up to 12TB 3200MT/s ECC DDR4 RDIMM/LRDIMM
  • Supports Intel® Optane™ persistent memory 200 series
  • View Memory Options
On-Board Devices
Chipset
  • Intel® C621
Network Connectivity
  • 2 RJ45 10GBASE-T with Intel® X710-TM4
  • 2 SFP+ 10GbE with Intel® X710-TM4
  • View AOC Options
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
NVMe
Input / Output
LAN
  • 1 RJ45 1 GbE Dedicated IPMI LAN port(s)
  • 2 RJ45 10 GbE LAN port(s)
  • 2 SFP+ 10 GbE LAN port(s)
USB
  • 2 USB 3.0 port(s) (rear)
Serial
  • 1 COM port(s) (Rear)
System BIOS
BIOS Type
  • AMI 32MB SPI Flash EEPROM
Management
Software
Power configurations
  • Power-on mode for AC power recovery
  • ACPI Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • System Lockdown
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory
  • 4+1 Phase-switching voltage regulator
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-218HTS-R2K08P
Dimensions and Weight
Height
  • 3.5" (89 mm)
Width
  • 17.3" (439.5 mm)
Depth
  • 31.6" (803 mm)
Package
  • 9.75" (H) x 26.5" (W) x 43.5" (D)
Weight
  • Gross Weight: 71.5 lbs (32.43 kg)
  • Net Weight: 45.5 lbs (20.64 kg)
Available Color
  • Black
Front Panel
LED
  • HDD activity
  • Network activity
  • Power status
  • System information (overheat/UID) 
Buttons
  • Power On/Off 
  • UID/ BMC Reset (Default)
Expansion Slots
PCI-Express (PCIe) Configuration
  • Default
    • 2 PCIe 3.0 x16 FHHL slot(s)
    • 4 PCIe 3.0 x8 (in x16) FHFL slot(s)
    • 1 PCIe 3.0 x16 (in x16) AIOM slot(s) (OCP 3.0 compatible)
  • View AOC Options
Drive Bays / Storage
Drive Bays Configuration
  • Default: Total 8 bay(s)
    • 8 front hot-swap 2.5" SATA drive bay(s)
  • Option A: Total 24 bay(s)
    • 24 front hot-swap 2.5" NVMe*/SAS*/SATA* drive bay(s)
  • (*NVMe/SAS/SATA support may require additional storage controller and/or cables, please see the optional parts list for details)
  • View Drive Options
M.2
System Cooling
Fans
  • 4x 8cm heavy duty fans with optimal fan speed control
Air Shroud
  • 8 Air Shroud(s)
Power Supply
2000W Redundant Titanium Level power supplies
Dimension (WxHxL)
  • 73.5 x 40 x 203 mm
+12V
  • Max: 83A / Min: 0A (100Vac-127Vac)
  • Max: 150A / Min: 0A (200Vac-220Vac)
  • Max: 165A / Min: 0A (220Vac-230Vac)
  • Max: 166A / Min: 0A (230Vac-240Vac)
12V SB
  • Max: 3.5A
AC Input
  • 1000W: 100-127Vac / 50-60Hz
  • 1800W: 200-220Vac / 50-60Hz
  • 1980W: 220-230Vac / 50-60Hz
  • 2000W: 220-240Vac / 50-60Hz (for UL only)
  • 2000W: 230-240Vac / 50-60Hz
  • 2000W: 230-240Vdc / 50-60Hz (for China only)
Output Type
  • Backplanes (gold finger)
Operating Environment
ROHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature: -40°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity: 8% to 90% (Non-Condensing)
  • Non-operating Relative Humidity: 5% to 95% (Non-Condensing)
Resources & Downloads
Parts List
Standard Parts (Parts Included)
Part Number Qty Description
Motherboard / Chassis MBD-X12QCH+

CSE-218HTS-R2K08P
1

1
Super X12QCH+ Motherboard

2U Chassis
Backplane BPN-NVME4-216N-S24 1 2U 24-slot all-hybrid direct-attached backplane, support 24x 2.5
Cable CBL-PWEX-0925 3 2x4,P3.0 to 2x4,P4.2,YL/RED,9.5A,55cm,16AWG,RoHS
CBL-SAST-1048 1 SLIMLINE SAS x8 to SLIMLINE SAS x8, INT, 10CM,32AWG,85
CBL-SAST-1208LP-85 4 SlimlineLP x8 (STR) to SlimlineLP x8 (STR),8CM,85 OHM,Ro
CBL-SAST-1235-85 1 Slimline x8 (STR) to Slimline x8 (STR),INT,35CM,85 OHM
CBL-SAST-1286-100 2 Slimline x4 (STR) to Slimline x4 (STR),INT,85CM,100 OHM,
CBL-CDAT-0679-66 1 [NR] FRONT CNTL,20 TO 20 PIN,PH0.5, FFC,FLAT,66CM,STD
CBL-PWCD-0160-IS 2 PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH
Drive Tray(s) MCP-220-00147-0B 8 Black gen-3 hot-swap 2.5"; Tool-less HDD tray (clip design)
MCP-290-21301-0B 2 Black 2.5\" HDD dummy cover for SC213,216 (Cover 8 HDD)
Air Shroud MCP-310-21812-0B 1 PSU air shroud for 218H,RoHS
Riser Card RSC-D2-668G4 1 2U LHS DCO Riser card with two PCIe 4.0 x16 and one PCIe
RSC-D2R-668G4 1 2U RHS DCO Riser card with two PCIe 4.0 x16 and one PCIe
Software SFT-OOB-LIC 1 License key for enabling OOB BIOS management
Heatsink / Retention SNK-P0078PW 4 2U Passive Wide CPU Heatsink (92x113x65mm) for X12 ICX/CPX CPU, Heatpipe
*Power Supply PWS-2K08A-1R 2 1U 2000W 100-240VAC Titanium Ultra power supply 73.5x40x203mm
*Fan FAN-0217L4 4 80x80x38 mm, 16.5K RPM, Hot-swappable Cooling Fan for SC218H
*Rail Set MCP-290-00057-0N 1 Rail set, quick/quick, default for 4U 17.2" W
MCP-290-00060-0N 1 Threaded rail adapter default for round hole rack
MCP-290-00115-0N 1 Inner rail, quick-release type
MCP-290-00117-0N 1 Outer rail, quick-release type
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Optional Parts List
Part Number Qty Description
2.5" SATA/SAS Drive Trays MCP-220-00147-0B 8 or 16 Black gen-3 hot-swap 2.5" Tool-less HDD tray (clip design)
CacheVault(s) MCP-240-00127-0N 1 BTR-CVPM05 Supercap mounting bracket for above power supply (support 1 BTR)
BTR-CVPM05 1 ~ 2 CacheVault for Broadcom RAID Controller (Ex. S3908/S3916)
MCP-240-00203-0N 1 BTR-CVPM05 Supercap mounting bracket for PCIe location (Support up to 2 BTR)
BTR-CV3108-U1 1 ~ 3 CacheVault for SMC 3108; Supercap mounted on chassis wall
Double Width GPU Kit SNK-P0077PW 4 1U Heatsink for CPUs ≤ 165W
MCP-240-21828-0N 1 GPU Brackets (Set L+R)
GPU power cable CBL-PWEX-1040 1/GPU GPU,2x4M/CPU to two (2x3F+2x1F)/PCIe,P4.2, 5CM,16/20AWG, 10.5A/pin(16AWG), 8A/pin(20AWG), -25~85C,RoHS
CBL-PWEX-1042 1/GPU GPU, 2x4F/CPU to 2x4F/CPU, P4.2, 50CM, 16AWG, 10A/pin, -40~105C
Intel NVMe RAID Controller AOC-VROCPREMOD - Intel VROC Premium, RAID 0, 1, 5, 10
AOC-VROCSTNMOD - Intel VROC HW key (RSTe) standard upgrade module
Low Profile Riser Kit(Per side) CBL-SAST-1307LPR-85 2 SlimSAS x8 (STR) to SlimSASLP x8 (RA) ,37CM,85Ohm,RoHS
CBL-SAST-1207LP-85 1 SlimlineLP x8 (STR,RSC) to Slimline x8 (STR),26CM,85 OH
CBL-PWEX-1172-2654 1 LP Riser power cable McHi,P3.0(2x4 to 2x2)+ to MnFt,2x4,PH4.2,26/54CM,9A/p,16
RSC-H2-68G4 1 Hyper riser card with one PCIe 4.0 x16 and one PCIe
MCP-240-21825-0N 1 Low profile riser bracket for SC218H
NVMe Support Kit CBL-SAST-1046 1 ~ 12 SLIMLINE SAS (LE) to SLIMLINE SAS, INT, 39CM,32AWG,85 Ohm (1 cable supports 2 NVMe U.2 Drives)
MCP-220-00167-0B 1 ~ 24 Tool-less black hot-swap 2.5" NVMe drive tray (Orange tab, w/ key lock, clip design)
RAID Controller 01-08pcs SATA3/SAS CBL-SAST-1281-100 1 Slimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM
AOC-S3908L-H8IR-16DD 1 8 int 12Gb/s ports, x8 Gen4, ROC - LP
RAID Controller 09-16pcs SATA3/SAS CBL-SAST-1296F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR),FFC,96/96CM,10
CBL-SAST-1281-100 1 Slimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM
AOC-S3916L-H16IR-32DD 1 16 int 12Gb/s ports, x8 Gen4, ROC - LP
RAID Controller 17-24pcs SATA3/SAS CBL-SAST-1296F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR),FFC,96/96CM,10
CBL-SAST-1281-100 2 Slimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM
AOC-S3916L-H16IR-32DD 1 16 int 12Gb/s ports, x8 Gen4, ROC - LP
AOC-S3908L-H8IR-16DD 1 8 int 12Gb/s ports, x8 Gen4, ROC - LP
TPM security module AOM-TPM-9670V 1 TPM module (Vertical) TPM 2.0
AOM-TPM-9671V 1 TPM module (Vertical) TPM 1.2
MP SuperServer SYS-240P-TNRT (Complete System Only )