| SYS-6028U-E1CNR4T+ |
- SuperServer 6028U-E1CNR4T+ (Black)
|
|
|
CPU |
- Intel® Xeon® processor E5-2600
v4†/
v3 family
(up to 160W TDP)
*
- Dual Socket R3 (LGA 2011)
|
Cores / Cache |
- Up to 22 Cores† / Up to 55MB† Cache
|
System Bus |
|
Note |
† BIOS version 2.0 or above is required |
Note |
* Please contact Supermicro Technical Support for additional information about frequency optimized CPUs and specialized system optimization.
|
|
|
Memory Capacity |
- 24x 288-pin DDR4 DIMM slots
- Up to 3TB† ECC 3DS LRDIMM, 1.5TB ECC RDIMM/LRDIMM
|
Memory Type |
- 2400†/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit
- 2666/2400 ECC DDR4 NVDIMM
|
DIMM Sizes |
- RDIMM:
64GB, 32GB, 16GB, 8GB, 4GB
- LRDIMM: 64GB, 32GB
- 3DS LRDIMM: 128GB
- NVDIMM: 16GB
|
Memory Voltage |
|
Error Detection |
- Corrects single-bit errors
|
|
|
Chipset |
|
SATA |
- SATA3 (6Gbps) with RAID 0, 1, 5, 10
|
IPMI |
- Support for Intelligent Platform Management Interface v.2.0
- IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
- ASPEED AST2400 BMC
|
Network Connectivity |
- 4x 10GBase-T ports via AOC-2URN4-i4XT
- Intel® X540 10GBase-T
- 1x Realtek RTL8211E PHY (dedicated IPMI)
|
Graphics |
|
|
|
SAS |
- 12x SAS3 ports support via expander and storage Add-on Cards
- One of the following storage Add-on cards required:
AOC-S3108L-H8iR-16DD (12Gbps SAS3/RAID 0, 1, 5, 6, 10, 50, 60, 2GB DDR3 cache, PCI-E Gen3 16 HDD)
AOC-S3108-H8iR (12Gbps SAS3/RAID 0, 1, 5, 6, 10, 50, 60, 2GB DDR3 cache, PCI-E Gen3)
AOC-S3008L-L8i (12Gbps SAS3/RAID 0,1 and 10, PCI-E Gen3)
AOC-S3008L-L8e (12Gbps SAS3/HBA, PCI-E Gen3)
|
NVMe |
|
LAN |
- 4x RJ45 10GBase-T LAN ports
- 1x RJ45 Dedicated IPMI LAN port
|
USB |
- 5x USB 3.0 ports
(2 rear, 2 onboard header, 1 Type A)
|
Video |
|
Serial Port / Header |
|
DOM |
- 2x SuperDOM (Disk on Module) ports
|
|
|
BIOS Type |
- 128Mb SPI Flash EEPROM with AMI BIOS
|
BIOS Features |
- Plug and Play (PnP)
- APM 1.2
- PCI 2.3
- ACPI 1.0 / 2.0 / 3.0 / 4.0
- USB Keyboard support
- SMBIOS 2.7.1
- UEFI 2.3.1
|
|
|
Software |
|
Power Configurations |
- ACPI Power Management
- Power-on mode for AC power recovery
|
|
|
| |
| Form Factor |
|
Model |
|
| |
| Width |
|
Height |
|
Depth |
|
Weight |
- Net Weight: 36 lbs (16.4 kg)
- Gross Weight: 72 lbs (32.7 kg)
|
Available Colors |
|
| |
| Buttons |
- Power On/Off button
- System Reset button
|
LEDs |
- Power status LED
- HDD activity LED
- 2x Network activity LEDs
- System information (overheat/UID) LED
|
|
|
PCI-Express |
- Up to 6x PCI-E 3.0 x8 slots
(4x FH, 10.5" L, 1x LP, 1x Internal LP)
(Both CPUs need to be installed for full access to PCI-E slots and onboard controllers. See manual block diagram and AOC Support for details.)
|
| |
| Hot-swap |
- 12x 3.5" Hot-swap drive bays
- Default 4x NVMe ports
- 12x SAS3 ports via Expander and AOC
Note: Storage Add-on card is required
|
| |
| Fans |
- 4x 8cm heavy duty PWM fans
|
| |
1000W Redundant Power Supplies with PMBus |
Total Output Power |
- 800W: 100 – 127Vac
- 1000W: 200 – 240Vac
- 1000W: 200 – 240Vdc (for CCC only)
|
Dimension (W x H x L) |
|
Input |
- 100-127Vac / 9.8 - 7A / 50-60Hz
- 200-240Vac / 7 - 5A / 50-60Hz
- 200-240Vdc / 7 - 5A (for CCC only)
|
+12V |
- Max: 66.7A / Min: 0A (100-127Vac)
- Max: 83A / Min: 0A (200-240Vac)
- Max: 83A / Min: 0A (200-240Vdc)
|
12Vsb |
|
Output Type |
- 25 Pairs Gold Finger Connector
|
Certification |
Titanium Level [ Test Report ]
|
|
|
Voltage |
- Monitors for CPU Cores, +1.8V, +3.3V, +5V, +12V, +3.3V Standby, +5V Standby, VBAT, Memory Voltages.
- 5+1 Phase-switching voltage regulator
|
FAN |
- 8x 4-pin fan headers
- Status monitor for speed control
- Pulse Width Modulated (PWM) fan connectors
|
Temperature |
- Support to monitor Supermicro AOC temperatures from IPMI or SD 5
- Monitoring for CPU and chassis environment
- CPU thermal trip support
- Thermal Control for 8x Fan Connectors
- Thermal Monitor 2 (TM2) support
- PECI
|
LED |
- Memory DIMM ECC error LEDs
- CPU / System Overheat LED
- Suspend static indicator LED
- UID/Remote UID
|
Other Features |
- 4x 8-pin GPU power connectors
- Chassis intrusion detection
- Chassis intrusion header
- SDDC Support
- RoHS
|
| |
| RoHS
|
|
Environmental Spec. |
- Operating Temperature:
10°C to 35°C (50°F to 95°F)
- Non-operating Temperature:
-40°C to 70°C (-40°F to 158°F)
- Operating Relative Humidity:
8% to 90% (non-condensing)
- Non-operating Relative Humidity:
5% to 95% (non-condensing)
|
|
|
|
| |
|
See Parts List
|
|
| |
|
|
Part Number
|
Qty
|
Description
|
Motherboard / Chassis |
MBD-X10DRU-i+
CSE-829UE1C4-R1K02-T |
1 1 |
Super X10DRU-i+ Motherboard
2U Chassis |
Add-on Card / Module |
AOC-2URN4-I4XT |
1 |
2U Ultra Riser based on Intel X540 controller with 4 10Gbase-T ports, 4 NVMe ports, and 1 internal PCI-E x8 3.0 slot |
Air Shroud |
MCP-310-82912-0N |
1 |
|
Backplane |
BPN-SAS3-826EL1-N4 |
1 |
12-port 2U SAS3 12Gbps single-expander backplane, support up to 8x 3.5-inch SAS3/SATA3 HDD/SSD and 4x NVMe/SAS3/SATA3 storage devices |
Cable 1 |
CBL-PWEX-0652 |
1 |
8 pin female to 2x RA(Right Angle) big 4 pin female power, 60/65CM, 18AWG,RoHS/REACH |
Cable 2 |
CBL-SAST-0658 |
4 |
MINI SAS HD,INT,PCIe NVMe SSD, 60CM,30AWG |
Cable 3 |
CBL-PWEX-0673 |
1 |
8 pin female to 2x big 4 pin female power, 65/70CM, 18AWG,RoHS/REACH |
Cable 4 |
CBL-SAST-0593 |
2 |
MINI SAS HD,12G,INT,60CM,30AWG |
Drive Tray(s) |
MCP-220-00116-0B |
4 |
Black gen-5 3.5-to-2.5 NVMe drive tray, Orange tab (for hotswap NVMe drive),RoHS/REACH |
Label |
LBL-0108 |
1 |
CAUTION LABEL FOR REDUNDANT PWR SYSTEMS |
Manual |
MNL-1751-QRG |
1 |
SYS-6028U-E1CNR(4)T+, QRG,HF,RoHS/REACH |
Riser Card |
RSC-R1UW-E8R |
1 |
1U RHS WIO Riser card with one PCI-E x8 slot |
Riser Card |
RSC-R2UW-4E8 |
1 |
2U LHS WIO Riser card with four PCI-E x4 slots |
Heatsink / Retention |
SNK-P0058PSU |
2 |
2U Passive CPU Heat Sink for X10 2U 24-DIMM Ultra Series Servers,RoHS/REACH |
Power Supply |
PWS-1K02A-1R |
2 |
1U 1000W Redundant Power Supply 73.5mm width Titanium Level,RoHS/REACH |
Mounting Rails |
MCP-290-00053-0N MCP-290-00060-0N |
1 1 |
Inner/outer rail set, quick-release type, 26.5" to 36.4" Threaded rail adapter default for round hole rack |
|
|
|
| |
| |
Part Number |
Qty |
Description |
Mounting Rails |
MCP-290-00053-0N MCP-290-00060-0N |
- - |
Inner/outer rail set, quick-release type, 26.5" to 36.4" Threaded rail adapter default for round hole rack |
2U Ultra optional rear drive kit |
MCP-240-82922-0N-OEM & MCP-240-82915-0N-OEM |
1 |
Rear 2x2.5" HDDs riser bracket kit for SC829U/219U, tool-less |
2U Cable Management Arm |
MCP-290-00128-0N & MCP-290-00127-0N |
1 |
2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42" in depth) |
Storage Control Card and Cable(s) |
AOC-S3008L-L8e
AOC-S3008L-L8i
AOC-S3108L-H8iR AOC-S3108L-H8iR-16DD
|
-
|
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60 Std LP, 8 internal ports, 12Gb/s per port- Gen3, 16HDD, RAID 0, 1, 5, 6, 10, 50, 60
|
Network Card(s) |
AOC-SGP-i2/4
AOC-STGN-i1S/i2S
AOC-STG-b4S
AOC-STG-i2T
AOC-STG-i2
AOC-S40G-i2Q
More |
-
-
-
-
-
-
- |
Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350
Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN
Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S
Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540
Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB
Standard LP 2-port 40GbE controller, based on Intel Fortville XL710
AOC Compatibility Matrix |
CacheVault(s) |
BTR-CV3108-U1 |
- |
CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra |
Hot-swap 3.5" to 2.5" Hard Disk Drive Tray |
MCP-220-00043-0N |
- |
Black hot-swap 3.5" to 2.5" HDD tray |
Global Services & Support |
OS4HR3/2/1 OSNBD3/2/1 |
- - |
3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service |
Software |
SFT-OOB-LIC • |
1 |
OOB Management Package (per node license) |
Software |
SFT-DCMS-Single |
1 |
DataCenter Management Package (per node license) |
Hide Parts List
|
|
|
|