SuperServer SYS-110P-WR

SYS-110P-WR Main SYS-110P-WR Angle SYS-110P-WR Top SYS-110P-WR Front SYS-110P-WR Rear
Integrated Board: X12SPW-F
Learn more

Key Applications

  • Virtualization
  • Cloud Computing
  • Enterprise Server
  • Data Center Optimized
  • Database Processing and Storage

Key Features

  1. Single Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors. Up to 270W TDP.
  2. 8 DIMMs; Supports 3DS DDR4-3200: RDIMM/LRDIMM/Intel® Intel® DCPMM
  3. 2 PCIe 4.0 x16 (FHFL) slots, 1 PCIe 4.0 x16 (LP) slot
  4. Intel® Ethernet Controller i210 2x 1GbE RJ45
  5. 10x hot-swap 2.5'' SATA3 drive bays with 4 hybrid NVMe/SATA drive bays, SAS3 with additional SAS controller card; Onboard 1x NVMe/SATA M.2
  6. Redundant Platinum 750W Power Supply
...
...
SYS-110P-WR
Specifications Resources & Downloads Parts List
Specifications
Product SKUs
SuperServer SYS-110P-WR
Motherboard
Super X12SPW-F
Processor
CPU
  • Single Socket P+ (LGA-4189)
  • 3rd Gen Intel® Xeon® Scalable processors
Core Count
  • Up to 40C/80T; Up to 60MB Cache
Note
  • Supports up to 270W TDP CPUs (Air Cooled)
System Memory
Memory
  • Slot Count: 8 DIMM slots
  • Max Memory (2DPC): Up to 2TB 3200MT/s ECC DDR4 RDIMM/LRDIMM
  • Supports Intel® Optane™ persistent memory 200 series
  • View Memory Options
Memory Voltage
  • 1.2V
On-Board Devices
SATA
  • SATA (6Gbps) ; RAID 0/1/5/10 support
NVMe
Chipset
  • Intel® C621A
Network Connectivity
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
Input / Output
LAN
  • 1 RJ45 1 GbE Dedicated IPMI LAN port(s)
  • 2 RJ45 1 GbE LAN port(s)
USB
  • 2 USB 2.0 port(s) (rear)
  • 2 port(s) (front)
  • 1 Type-A port(s)
  • 2 port(s) (header)
  • 2 port(s) (rear)
Video
  • 1 VGA 2.0 port(s)
DOM
  • 2 SuperDOM (Disk on Module) port(s) with built-in power
System BIOS
BIOS Type
  • AMI 32MB SPI Flash EEPROM
Management
Software
Power configurations
  • ACPI/APM Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • System Lockdown
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory
  • 7+1 Phase-switching voltage regulator
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 1U Rackmount
Model
  • CSE-116TS-R706WBP4
chassisWeight
  • Net Weight: 25 lbs (11.34 kg)
  • Gross Weight: 38 lbs (17.24 kg)
Dimensions and Weight
Height
  • 1.7" (43 mm)
Width
  • 17.2" (437 mm)
Depth
  • 23.5" (597 mm)
Package
  • 8" (H) x 24" (W) x 32" (D)
Weight
  • Gross Weight: 38 lbs (17.24 kg)
  • Net Weight: 25 lbs (11.34 kg)
Available Color
  • Black
Front Panel
LED
  • Device Activity
  • LAN 1 Activity
  • LAN 2 Activity
  • Power status
  • System information
Buttons
  • Power On/Off 
  • UID button
Expansion Slots
PCI-Express (PCIe) Configuration
Drive Bays / Storage
Drive Bays Configuration
  • Default: Total 10 bay(s)
    • 10 front hot-swap 2.5" SATA drive bay(s)
  • Option A: Total 10 bay(s)
    • 6 front hot-swap 2.5" SATA drive bay(s)
    • 4 front hot-swap 2.5" NVMe drive bay(s)
  • View Drive Options
M.2
System Cooling
Fans
  • 1 AOC cooling Fan(s) (optional)
  • 5 counter-rotation PWM 40x40x56mm Fan(s)
Power Supply
750W Redundant Platinum Level power supplies
Dimension (WxHxL)
  • 54.5 x 40.25 x 320 mm
+12V
  • Max: 58A / Min: 0.5A (100Vac-140Vac)
  • Max: 62A / Min: 0.5A (200Vac-240Vac)
5V SB
  • Max: 3A / Min: 0A
AC Input
  • 700W: 100-140Vac / 50-60Hz
  • 750W: 200-240Vac / 50-60Hz
Output Type
  • Backplanes (gold finger)
Certification
Operating Environment
Environmental Spec.
  • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)
  • Operating Relative Humidity: 8% to 90% (non-condensing)
  • Non-operating Relative Humidity: 5% to 95% (non-condensing)
Resources & Downloads
Parts List
Standard Parts (Parts Included)
Part Number Qty Description
Motherboard / Chassis MBD-X12SPW-F

CSE-116TS-R706WBP4
1

1
Super X12SPW-F Motherboard

1U Chassis
Backplane BPN-SAS3-LB16A-N10 1 1U 10-Slot SFF Hybrid Backplane Supports 10xSAS3/SATA3/NVMe4 Storage Devices with 1x(2x4) + 2x(1x4) + 1x(2x2) Power Connectors
Cable CBL-SAST-1234A-100 1 SlimSAS x4 (STR) to 4x SATA,65CM,100 OHM,RoHS
CBL-SAST-1285-100 2 Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM,R
CBL-0335L 1 FRONT CTL CABLE 20 PIN TO 20 PIN W/TUBE,70CM,PBF
CBL-PWCD-0160-IS 2 PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH
Fan FAN-0141L4 5 40x40x56 mm 20.5K RPM / 17.6K RPM Counter-rotating Fan
Manual MNL-2265-QRG 1 110P-WTR Quick Reference Guide
Riser Card RSC-W-66G4 1 1U LHS WIO Riser card with two PCIe 4.0 x16 slots,HF,RoHS
RSC-WR-6 1 1U RHS WIO Riser card with one PCIe 4.0 x16 slot,HF,RoHS
Software SFT-OOB-LIC 1 License key for enabling OOB BIOS management
Heatsink / Retention SNK-P0077P 1 1U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms
*Power Supply PWS-706P-1R 2 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF
MCP-250-00009-0N 1 SC113 Redundant Power Distributor Cover
*Power Distributor PDB-PT112-S2424 1 WIO X11 Support,PDB-PT112-S2424 is based on PDB-PT112-2424
*Front Panel FPB-FP116-DU3 1 Front control board with two USB 3.0 for SC116/SC119X
*Parts MCP-120-00029-0N 2 Blank FH L bracket without SCSI cutout for SC815,823
MCP-120-00030-0N 1 Blank LP L-bracket (1 raw of capsule hole)
*Drive Tray(s) MCP-220-00047-0B 10 Black gen 3rd hot-swap 2.5inch HDD tray
*Rear Window MCP-240-00098-0N 1 WIO rear window for SC113,SC116, SC815 Redundant PWS
*Rail Set MCP-290-00016-0N 1 1U open rack bracket set for CSE-PT51L,MCP-290-00054-0N
MCP-290-00063-0N 1set Rail set, quick/quick, default for 1U 17.2"W for SC113/SC116,RoHS/REACH
*Air Shroud MCP-310-19002-0N 1 SC815/113/116 Intel DP X9, X8 PC air shroud, 12x13MB
*Fan Holder MCP-320-00027-0B 24 Plastic pin for 40x28, 40x56 fan
MCP-320-00028-0B 1 Fan holder for 6pcs 40x56 fan, assemble-able for SC819/SC119/SC818/SC116
MCP-340-00035-0B 2 Dummy fan 40x56mm for 40x56 counter-rotating fan (cost-effective)
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Optional Parts List
Part Number Qty Description
CacheVault BTR-CV3916-1U1 (For S3908/S3916) 1 CacheVault for Broadcom 3908/3916 with SuperCap mounting in 1U 40x56 fan tray
BTR-CVPM05 + MCP-240-00203-0N (For S3908/S3916) 1 CacheVault for Broadcom 3908/3916 with SuperCap mounting bracket for PCIe location
BTR-TFM8G-LSICVM02 + MCP-240-00203-0N (For S3108) 1 CacheVault for Broadcom 3108 with SuperCap mounting bracket for PCIe location
BTR-CV3108-1U1 (For S3108) 1 CacheVault for Broadcom 3108 with SuperCap mounting in 1U 40x56 fan tray
Cooling Fan FAN-0141L4 1 40x40x56 mm, 20.5K RPM / 17.6K RPM, Counter-rotating Fan
Front Bezel MCP-210-11601-0B 1 Black Front Bezel
Inlet Thermal Sensor MCP-280-00033-0N 1 Universal Thermal sensor kit with 80cm I2C cable
Intel VROC RAID Key for NVMe AOC-VROCPREMOD 1 Premium Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10/5
AOC-VROCINTMOD 1 Intel SSD Only Upgrade module; RAID 0/1/10/5
AOC-VROCSTNMOD 1 Standard Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10
NVMe Cable(s) CBL-SAST-1231-85 - Slimline x8 (STR) to Slimline x8 (STR),INT,30CM, 85 OHM
NVMe Drive Try(s) MCP-220-00167-0B - Tool-less Hot-swap Gen-3 NVMe drive tray, Orange tab, Black
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)
Storage Control Card and Cable(s) AOC-S3916L-H16iR-32DD + 2x CBL-SAST-1261-100 1 Standard LP, 16 internal ports (12Gb/s) PCIe 4.0 x8, 32HDD; RAID 0, 1, 5, 6, 10, 50, 60
AOC-S3108L-H8iR-16DD 1 Standard LP, 8 Internal ports (12Gb/s) PCIe 3.0 x8, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60
AOC-S3008L-L8I 1 Standard LP, 8 internal ports (12Gb/s) PCIe 3.0 x8, 63HDD; RAID 0, 1, 10
AOC-S3908L-H8iR-16DD + 1x CBL-SAST-1261-100 1 Standard LP, 8 internal ports (12Gb/s) PCIe 4.0 x8, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60
Storage Control Card and Cable(s) (HBA) AOC-S3008L-L8E 1 Standard LP, 8 internal ports (12Gb/s) PCIe 3.0 x8, 122HDD; HBA
AOC-S3808L-L8IT + 1x CBL-SAST-1261-100 1 Standard LP, 8 internal ports (12Gb/s) PCIe 4.0 x8, 122HDD; HBA
AOC-S3816L-L16IT + 2x CBL-SAST-1261-100 1 Standard LP, 16 internal ports (12Gb/s) PCIe 4.0 x8, 122HDD; HBA
TPM AOM-TPM-9670V-S-O 1 TPM 2.0, vertical form factor, provisioned for server
AOM-TPM-9671V-S-O 1 TPM 1.2, vertical form factor, provisioned for server
UP SuperServer SYS-110P-WR
  1. Products
  2. Systems
  3. UP
  4. SYS-110P-WR