My server SYS-121H-TNR has been experiencing random reboots during peak business hours.
I'm getting the following errors from the BMC Health Event Log:
2024-05-20 14:35:28 ProcessorConfiguration [PC-0001] Configuration error - CPU 2 IFU BUS Fatal error(Last Boot error) - Assertion Sensor-specific
2024-05-20 14:35:28 ProcessorConfiguration [PC-0001] Configuration error - CPU 2 DCU BUS Fatal error(Last Boot error) - Assertion Sensor-specific
2024-05-20 14:35:28 ProcessorConfiguration [PC-0001] Configuration error - CPU 1 PCU Unknown Fatal error(Last Boot error) - Assertion Sensor-specific
2024-05-20 14:34:03 CPLD [CPLD-0036] MCERR - Assertion Sensor-specific
Please diasble the C6 State in the BIOS.
Advanced -> CPU Configuration -> Advanced Power Management Configuration -> Package C State Control
Package C State: [C2 State]