Question
My server SYS-121H-TNR has been experiencing random reboots during peak business hours.

I'm getting the following errors from the BMC Health Event Log: 
2024-05-20 14:35:28 ProcessorConfiguration [PC-0001] Configuration error - CPU 2 IFU BUS Fatal error(Last Boot error) - Assertion Sensor-specific
2024-05-20 14:35:28 ProcessorConfiguration [PC-0001] Configuration error - CPU 2 DCU BUS Fatal error(Last Boot error) - Assertion Sensor-specific
2024-05-20 14:35:28 ProcessorConfiguration [PC-0001] Configuration error - CPU 1 PCU Unknown Fatal error(Last Boot error) - Assertion Sensor-specific
2024-05-20 14:34:03 CPLD [CPLD-0036] MCERR - Assertion Sensor-specific

Print
Answer
Please diasble the C6 State in the BIOS. 

Advanced -> CPU Configuration -> Advanced Power Management Configuration -> Package C State Control 

Package C State: [C2 State]
Was this FAQ helpful?
Enter Comments Below:
Note: Your comments/feedback should be limited to this FAQ only. For technical support, please send an email to .
Enter your email address below if you'd like technical support staff to reply:
Please type the Captcha (no space)
B W R T
Find more questions