SuperServer SYS-221P-C9R

2U Mainstream with 5 PCIe 5.0 slots and dual 1GbE LAN

SYS-221P-C9R Main SYS-221P-C9R Angle SYS-221P-C9R Top SYS-221P-C9R Front SYS-221P-C9R Rear
Integrated Board: X13DEI
Learn more

Key Applications

  • Virtualization
  • Enterprise Server
  • Application and data serving
  • Compute Intensive Applications

Key Features

  1. Dual Socket E (LGA-4677) 5th/4th Gen Intel® Xeon® Scalable processors,supports up to 300W TDP
  2. 16 DIMM slots, Up to 4TB DDR5-5600MHZ/4800MHz ECC Registered RDIMM
  3. 4 PCIe 5.0 x16 Low Profile (LP), 1 PCIe 5.0 x8 Low Profile (LP)
  4. 16 hotswap 2.5" drive bays with 8 SAS RAID (0, 1, 5, 6, 10, 50, 60) and 8 SATA drive support
  5. 1200W Redundant Titanium level Power Supplies
...
...
SYS-221P-C9R
Specifications Resources & Downloads Parts List
Specifications
Product SKUs
SuperServer SYS-221P-C9R
Motherboard
Super X13DEI
Processor
CPU
Note
  • Supports up to 300W TDP CPUs (Air Cooled)
System Memory
Memory
  • Slot Count: 16 DIMM slots
  • Max Memory (1DPC): Up to 4TB 5600MT/s ECC DDR5 RDIMM
  • View Memory Options
On-Board Devices
Chipset
  • Intel® C741
Network Connectivity
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
NVMe
Input / Output
LAN
  • 1 RJ45 1 GbE Dedicated BMC LAN port(s)
USB
  • 2 USB 2.0 port(s) (front)
  • 4 USB 3.0 port(s) (rear)
Video
  • 1 VGA port(s)
Serial
  • 1 COM port(s) (Rear)
  • 1 COM port(s) (Front)
DOM
  • 2 SuperDOM (Disk on Module) port(s)
TPM
  • 1 TPM Onboard/port 80
System BIOS
BIOS Type
  • AMI 32MB SPI Flash EEPROM
Management
Software
Power configurations
  • ACPI/APM Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • Supply Chain Security: Remote Attestation
  • Runtime BMC Protections
  • System Lockdown
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-213BTS-R1K23LPBP3-1
chassisWeight
  • Net Weight: 38 lbs (17.4 kg)
  • Gross Weight: 63 lbs (28.8 kg)
Dimensions and Weight
Height
  • 3.5" (89 mm)
Width
  • 17.2" (437 mm)
Depth
  • 24.8" (630 mm)
Package
  • 11" (H) x 29" (W) x 38.7" (D)
Weight
  • Gross Weight: 63 lbs (28.8 kg)
  • Net Weight: 38 lbs (17.4 kg)
Available Color
  • Black
Front Panel
LED
  • HDD activity
  • Network activity
  • Power status
  • System information (overheat/UID) 
Buttons
  • Power On/Off 
  • System Reset
Expansion Slots
PCI-Express (PCIe) Configuration
M.2
  • 2 M.2 PCIe 4.0 x2 NVMe slot(s) (M-key)
Drive Bays / Storage
Drive Bays Configuration
  • Default: Total 16 bay(s)
    • 4 front hot-swap 2.5" NVMe*/SAS drive bay(s)
    • 4 front hot-swap 2.5" SAS drive bay(s)
    • 8 front hot-swap 2.5" SATA drive bay(s)
  • (*NVMe support may require additional storage controller and/or cables, please see the optional parts list for details)
  • View Drive Options
M.2
Peripheral Bays
  • 1 slim DVD bay(s) (optional)
System Cooling
Fans
  • 3x 8cm heavy duty fans with optimal fan speed control
Power Supply
1200W Redundant Titanium Level power supplies
Dimension (WxHxL)
  • 76 x 40 x 336 mm
+12V
  • Max: 83A / Min: 0A (100Vac-127Vac)
  • Max: 100A / Min: 0A (200Vdc-240Vdc)
  • Max: 100A / Min: 0A (200Vac-240Vac)
5V SB
  • Max: 4A / Min: 0A
AC Input
  • 1000W: 100-127Vac / 50-60Hz
  • 1200W: 200-240Vac / 50-60Hz
  • 1200W: 200-240Vdc / 50-60Hz (for CCC only)
Output Type
  • Backplanes (gold finger)
Operating Environment
ROHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature: -30°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity: 8% to 80% (non-condensing)
  • Non-operating Relative Humidity: 8% to 90% (non-condensing)
Resources & Downloads
Parts List
Standard Parts (Parts Included)
Part Number Qty Description
Motherboard / Chassis MBD-X13DEI

CSE-213BTS-R1K23LPBP3-1
1

1
Super X13DEI Motherboard

2U Chassis
Add-on Card / Module AOC-S3908L-H8IR-16DD-P 1 8 int 12Gb/s ports, x8 Gen4, ROC - LP, 16 HDDw/ exp,RoHS
Backplane BPN-SAS4-213A-N8 1 2U 16-slot SFF 2.5" SAS4 direct-attached backplane, 1st 8 slots also support NVMe Gen5.,RoHS
Cable CBL-PWEX-1109-10 2 MicroFit,2x4,PH3.0,F to 2x BIG,1x4,PH5.08,M,10CM,10A/pin
CBL-SAST-1261-100 2 Slimline x8 (STR) to 2x Slimline x4 (STR),60/60CM,100 O
CBL-0071L 1 ROUND 16 TO 16 PIN RIBBON FP CABLE 30"L, LF
CBL-0217L 1 16PIN CNTL PANEL CONVERTER CBL FOR SC826,PBF
CBL-PWCD-0160-IS 2 PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH
CBL-PWEX-1069 3 PWEX,FAN,1X4/P2.5 TO 1X4/P2.54,30CM,22AWG,5A/pin,RoHS
Drive Tray(s) MCP-220-00007-01 1 Black USB/COM port tray for SC825, 836
MCP-220-00009-01 1 Black 5.25"; drive tray w/o rail (square pattern)
MCP-220-00023-01 1 Black USB dummy tray support 1x 2.5" slim HDD for SC825, 836
MCP-220-00047-0B 16 Black gen 3rd hot-swap 2.5inch HDD tray
Parts MCP-260-00042-3N 1 STD I/O shield for X13 server MB with venting holes
Manual MNL-2566-QRG 1 221P-C9R(T) Quick Reference Guide
Software SFT-OOB-LIC 1 License key for enabling OOB BIOS management
Heatsink / Retention SNK-P0088P 2 2U Passive CPU HS for X13 EGS and X14-SP BHS-SP Systems
*Power Supply PWS-1K23A-1R 2 AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 336x76x40 mm,HF,RoHS/REACH
*Power Distributor PDB-PT829-S8824 1 PDB with 23pairs input connectors for SC829B216B
*Fan FAN-0206L4 3 80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers
*Front Panel FPB-FP826-D 1 Front control board Dual color LED(FP826-D)forSC826,213,216,
FPB-TB826 1 16 pin Cable Adaptor Board for SC826
*Rear Window MCP-240-82608-0N 1 216B/826B LP rear window,RoHS/REACH,PBF
*Peripheral Drive MCP-290-00007-01 1 Black DVD dummy cover for SC825, 836
*Rail Set MCP-290-00053-0N 1 Rail set, quick/quick, default for 2,3U 17.2"W
MCP-290-00060-0N 1 Threaded rail adapter default for round hole rack
*Air Shroud MCP-310-29001-0N 1 SC825/826/216/213 Intel DP X9,X8 air shroud 13.68x13/12x13
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Optional Parts List
Part Number Qty Description
Management Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)
Optional 2x front fixed SATA drive Kit 1x MCP-220-00044-0N, 2xCBL-SAST-0624+1*CBL-0082L 1 1x MCP-220-00044-0N can support 2x 2.5 inch fixed drives in 1x 5.25 inch drive bay
Optional 2x Rear hot-Swap SATA drive Kit 1x 1xMCP-220-82616-0N+1xCBL-0182L 1 1x MCP-220-82616-0N can support 2x 2.5 inch fixed drives in Rear side
Optional 16-ports SAS Raid controller kit 1xAOC-S3916L-H16IR-32DD-O 1 Standard LP, 8 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60
Optional 2U Cable Management Arm Kit 1 x MCP-120-82503-0N+1 x MCP-290-00073-0N 1 2U Cable Management Arm Kit
Optional 8-ports SAS Raid controller kit 1x AOC-S3908L-H8IR-16DD-O 1 Standard LP, 8 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60
Optional CacheVaults Kit 1xBTR-CVPM05+1x MCP-240-00203-0N 1 CacheVault for Broadcom 3908/3916 with Supercap and PCI bracekt
Optional Front Hot-Swap NVMe Kit 1xCBL-MCIO-1260M5 for 2 U.2 NVMe Drives 1 NVMe Kit for front hot-swap NVMe . Max. 4 NVMe support
Optional Front Slim ODD Kit 1xDVM-TEAC-DVD-SBT5+1x MCP-220-81502-0N 1 BLACK TEAC SLIM DVD SATA DRIVE
Optional MCC CPU Carrier 1x SKT-1424L-001B-FXC 1 CPU Carrier for Intel Socket-E ( LGA4677) E1B MCC CPU
Optional Trusted Platform Module 1x AOM-TPM-9672V-FIPS-O 1 AOM-TPM-9672V-FIPS TPM 2.0 support FIPS
1x AOM-TPM-9672V-O 1 SPI capable vertical TPM 2.0
Optional XCC CPU Carrier 1x SKT-1333L-0000-FXC 1 CPU Carrier for Intel Socket-E ( LGA4677) E1A XCC CPU
Mainstream SuperServer SYS-221P-C9R New