Question
I'm using a H8DME-2 motherboard with Linux. I just installed latest SuperOdoctor II from your FTP site, but when running SDT I see that SDII monitors Fan 1 to FAN 8, I'm only have a fan installed at FAN position 1 to 3, so FAN 4 to 8 are marked as failed (Warning!). How can I turn off the fan monitoring for FAN 4 to 8?
Print
Answer
Please Alter the file called superd.ine at: etc/superd.ini . In the file you will find that for FAN 4 to 8, the line "Monitor=True" is available.
Please change this Line to "Monitor=false"